DO NOT MOUNT WHERE AMBIENT TEMPERATURE IS OUTSIDE THE RANGE OF -10
INPUT
VOLTAGE
120 VAC
120 VAC
120 VAC
120 VAC
240 VAC
240 VAC
240 VAC
240 VAC
NOTE: * With suitable external heatsink (where 130 extrusion temperature does not exceed 70° C.), maximum rating for
Output Amps can be increased to 10 ADC output at up to 1Hp at 90VDC or 2Hp at 180VDC.
1. Size all wires which carry armature or line currents AS SPECIFIED BY NATIONAL, STATE, AND/
OR LOCAL CODES. All other wires may be # 18 AWG or smaller as permitted by local code.
2. Separate control wires from the armature and AC lines when routed in conduit or in wire trays.
3. Fusing - The motor and control are protected against overloads by the current limit circuit and a
customer installed fuse in the AC line. THIS PROTECTION ALREADY MAY BE PROVIDED BY
THE CUSTOMER WITH CIRCUIT BREAKERS OR FUSES IN BOTH MAIN LINES. IF NOT:
FOR 120 VAC INPUT - fuse or breaker protection should be added by the customer inline with
the Hot AC Line (see following chart).
FOR 240 VAC INPUT - fuse or breaker protection should be added by the customer inline with
both Hot AC Lines (see following chart).
FUSING ADDED BY CUSTOMER (Bussman ABC or Little Fuse 314 Series ceramic fuses)
HORSEPOWER
1/50
1/20
1/8
¼
1/3
½
¾
1.0
1.5
2.0
TERMINAL STRIP WIRING INSTRUCTIONS
Upper board terminal block connections (P4)
P4-1
(AC1 / L) – For single phase AC lines, (120VAC for US or 240VAC for Europe) connect the Hot
side of your AC line to this terminal. For systems with two hot AC lines, (240VAC for US)
connect either of the Hot AC lines to this terminal.
P4-2
(AC2 / N) – For single phase AC lines, (120VAC for US or 240VAC for Europe) connect the
Neutral side of your AC line to this terminal. For systems with two hot AC lines, (240VAC for
US) connect either of the Hot AC lines to this terminal.
MODEL SELECTION
OUTPUT
VOLTAGE
0-90 VDC
0-90 VDC
0-90 VDC
0-90 VDC
0-180 VDC
0-180 VDC
0-180 VDC
0-180 VDC
WIRING PROCEDURE & FUSING
120 VAC INPUT
CAUTION:
MODEL
OUTPUT*
NUMBER
AMPS DC
130LC12
1.2 ADC
130LC100
5.5 ADC*
130HC12
1.2 ADC
130HC100
10 ADC*
132LC25
1.2 ADC
132LC200
5.5 ADC*
132HC25
1.2 ADC
132HC200
10 ADC*
2 AMP
2 AMP
3 AMP
4 AMP
6 AMP
8 AMP
12 AMP
15 AMP
----------
----------
4
C (15
F) TO 45
C (115
F)
o
o
o
o
HORSEPOWER
1/50 – 1/8
1/8 – 1/2*
1/50 – 1/8
1/8 – 1
1/25 – 1/4
1/4 – 1*
1/25 – 1/4
1/4 – 2
240 VAC INPUT
----------
1 AMP
2 AMP
3 AMP
3 AMP
4 AMP
6 AMP
8 AMP
12 AMP
15 AMP