Note:
Description on cleaning level: When setting the Filter Clean Reminder Function,
timer zone will display 2 digits, of which the form
operating place and the latter indicates the operating time of indoor unit. There are 4
types of situations:
Cleaning
Level
Turn off
Timer zone shows 00
Clean
The former digit shows 1 while the latter one shows 0, which indicates the
Slight
accumulating operating time is 5500 hours. Each time the latter digit increases 1, the
Pollution
operating time increases 500 hours. When it reaches 9, it means the operating time
is 10000 hours.
The former digit shows 2 while the latter one shows 0, which indicates the
Medium
accumulating operating time is 1400 hours. Each time the latter digit increases 1, the
Pollution
operating time increases 400 hours. When it reaches 9, it means the operatin g time
is 5000 hours.
The former digit shows 3 while the latter one shows 0, which indicates the
Heavy
accumulating operating time is 100 hours. Each time the latter digit increases 1, the
Pollution
operating time increases 100 hours. When it reaches 9, it means the operating time
is 1000 hours.

4.13 X-FAN SETTING

X-fan Function: If unit is turned off under Cooling or Dry mode, the evaporator of
indoor unit will be dried off automatically to prevent bacteria and mould from gathering.
Turn on X-fan: When unit is on or under Cooling or Dry mode, press FUNCTION
button to select X-fan. "
turn on this function.
Turn off X-fan: When X-fan function is on, press FUNCTION button to select X-fan.
"
" icon will blink. Then press ENTER/CANCEL button to turn off this function.

4.14 OUT SETTING

Out Function: This is used to maintain indoor temperature so that unit can realize
fast heating after it is turned on. This function can only be used under Heating mode.
Turn on Out Function: Under Heating mode, press FUNCTION button to select Out.
"
" icon will blink. Then press ENTER/CANCEL button to turn on this function.
Turn off Out Function: When this function is on, press FUNCTION button to select
Out. "
" icon will blink. Then press ENTER/CANCEL button to turn off this function.
er indicates the pollution degree of
Description of Levels
" icon will blink. Then press ENTER/CANCEL button to
28