NOTE: SIDE TERMINAL TO BE USED IN POSITIVE CLAMP ONLY!
20.
section 17e or 17f.
Storage position
Will not get lost. Always ready to use.
LENGTH OF CHARGE
21.
a.
Test the battery for state of charge. Do not charge if it is over 75% charged or the battery is determined to be defective.
b.
Set beginning amps charge rate for size of battery and state of charge per charts
c.
Charge for length of time per charge,
d.
Discontinue charge when the specific gravity of electrolyte reaches 1.260 or above. A temperature compensating hydrometer should be used
for this reading. Discontinue charge if the battery begins to gas excessively or if the temperature of the electrolyte reaches approximately
125°F. Do not overcharge batteries. Overcharging results in excessive water loss and eventual damage to the battery.
BATTERY SIZE
Ampere Hours
Reserve Capacity
Cold Cranking Amps
STATE OF CHARGE TABLE
STATE OF CHARGE
Specific Gravity
Open Circuit Voltage-6 V.
Open Circuit Voltage-12 V.
Open Circuit Voltage-24 V.
ASSEMBLY INSTRUCTIONS
Attach the handle to the charger using the four screws provided.
OPERATING INSTRUCTIONS
CAUTION
- This battery charger must be fully assembled before operating. Failure to do so may result in risk of injury.
USE OF INSTRUMENT PANEL:
The CHARGE TIME timer has an OFF position, a CONTINUOUS CHARGE position and a timed charge range from 0 to
120 minutes.
a. OFF - Always make sure the timer is in the OFF position before connecting or disconnecting the clamps from the
battery. The charger will not charge with the timer in this position.
b. CONTINUOUS CHARGE - This position is used for slow charging or parallel charging and will not turn the charger off.
Do not use this position for fast charging.
c. 0 to 120 MINUTES TIMED CHARGE - The timer will automatically turn the charger off at the end of the pre-set
charging time. Turn the timer past 20 before setting the desired time.
TO CHARGE BATTERIES
Make connections to the battery per the instructions in previous sections of this manual.
Determine if the battery is 6, 12 or 24 volts and then set the CHARGE VOLTAGE switch to 6V for a 6 volt battery, 12LO for a 12 volt battery or 24V for a
24 volt battery.
Turn the timer on and read the AMPERES meter.
If a higher rate of charge is desired for charging 12 volt batteries, set the CHARGE VOLTAGE switch to the 12HI position.
Set the timer to the desired minutes charge.
DO NOT USE THE 12V START POSITION TO CHARGE BATTERIES.
Extended position
Note: Pressure, when handle is squeezed,
holds adapter firm. Will not slip back.
BATTERY SIZE TABLE
SMALL
MEDIUM
LARGE
40
60
80+
60
90
100+
275
350
400+
75%
50%
25%
DEAD
1.225
1.185
1.140
1.110
5.9
6.2
6.05
5.95
11.8
12.4
12.1
11.9
24.8
24.2
23.8
23.6
For instructions for NEGATIVE clamp attachment refer to
Thrust on terminal
Note: Clamp is released and spring
tension holds adapter firm.
CHARGE RATE Vs. MINUTES CHARGE
BATTERY SIZE %CHARGE
0-25
SMALL
25-50
A
M
50-75
P
0-25
E
MEDIUM
25-50
R
E
50-75
S
0-25
LARGE
25-50
50-75
3
MINUTES
15 30 45 60 75 90
45
30
30
25
25
20
30
20
20
15
15
10
15
10
10
10
5
5
70
50
45
40
35
30
45
30
25
20
20
20
25
15
15
10 10 10
90
55
55
50
45
45
60
40
35
30
30
30
30
20
20
15 15 15