• Use an air hose with minimum 9 mm inner diameter (see warnings),
e.g. Art. No. 53090.
1. Check if all screws [2-1], [2-2], [2-3], [2-4] and [2-5] have been tight-
ened firmly. Tighten fluid tip [2-1] firmly by hand (12 Nm) according to
[7-4]. Check if locking screw [2-5] has been firmly tightened according
to [10-1]. Tighten, if necessary.
2. Rinse material passages with suitable cleaning solution [2-6], ob-
serve chapter 8.
3. Adjust air cap: vertical spray fan [2-7], horizontal spray fan [2-8].
4. Insert paint strainer [2-9] and install gravity flow cup [2-10].
5. Fill gravity flow cup (max. 20 mm below upper edge), close with the lid
[2-11] and insert anti-drip device [2-12].
6. Screw connection nipple [2-13] (not included in delivery) onto the air
inlet.
7. Connect compressed air hose [2-14].
7.1. Adjust spray gun inlet pressure
• Pull the trigger fully and adjust the spray gun inlet pressure (see
chapter 2) following instructions of one of the followig sections ([3-1],
[3-2], [3-3] to [3-4]), then release the trigger.
• With [3-2], [3-3] and [3-4], the air micrometer [1-13] has to be fully
opened and in vertical position.
• If the required spray gun inlet pressure is not reached, the pressure
at the compressed air circuit has to be increased; too high pressure
results in too high trigger forces.
[3-1] SATA adam 2 mini (accessory / accurate method).
[3-2] Separate gauge with control device (accessory).
[3-3] Separate gauge without control device (accessory).
[3-4] Pressure regulation at the compressed air circuit (least ac-
curate method): rule of thumb: pressure at the pressure reducer
must be set 0.6 bar higher than the recommended spray gun inlet
pressure per every 10 m of air hose (inner width 9 mm).
106
Note!
Note!