At the bottom of the screen you will see next options:
SLOW / FAST [F1]:
AVG / MAX / PEAK [F2]:
DIGITAL / ANALOG /
SLM [F3]:
SCAN [F4]:
LEVEL / CHAN / FREQ /
SPAN [F5]:
NOTE:
Access to the function SCAN / SPECTRUM switches depending on the type of
tuning you are doing.
In case you are tuning a signal using frequency, it will be displayed the
SPECTRUM function first.
In case you are tuning a signal using the predefined channels from the channel
plan, it will be displayed the SCAN function first.
4.2.5.4.3

LOGGER function

To access the LOGGER function:
1.- Press key
2.- Press softkey TV [F2].
3.- Press softkey LOGGER [F4].
Page 54
It can be changed the scanning speed.
It can be changed the measurement mode. The current
mode appears below the selected channel. In the
AVERAGE option it makes an average of values; in the
MAX HOLD option, it keeps the maximum values
measured due to impulsive signals, remaining on the
screen with dotted lines; PEAK option uses as
reference the peak values.
It leads to the first screen of the measurement mode
(This option changes regarding to the screen you
come).
It goes to the SCAN screen (refer to section 4.2.5.4.1).
Pressing this key you can navigate among editable
parameters. To change them, use the Cursor keys or
the alphanumeric keypad as appropriate. It can be
edited the LEVEL, to change the margin of the power
on the vertical axis of the graph, CHANNEL, to change
the channel we are analysing; FREQUENCY, to change
the frequency; SPAN, to change the frequency range
shown on the horizontal axis of the graph.