xChargeIn
Connection cross-section of the supply
●
●
Cross-section
●
●
AWG:
Stripping length:
Flathead screwdriver:
Temperature rating:
12.3
Cable / Socket
Cable versions
Socket variants:
*)
For rating, see rating plate on the cable
12.4
Ambient conditions
Operating temperature
●
●
Storage temperature:
Relative air humidity:
Altitude:
Rate of temperature change:
Installation manual V1.01
© EATON
16 A rated current:
32 A rated current:
Rigid / flexible:
Flexible with wire end sleeve with / with-
out plastic sleeve:
*)
:
16 A:
32 A:
Minimum cross-section (depending on the
cable and the type of installation)
2
●
5 x 2.5 mm
2
●
5 x 6.0 mm
2
●
0.2 – 16 mm
2
●
0.25 – 10 mm
24 – 6
12 mm
5.5 mm
105 °C
Type1 cable: up to 32A / 230V AC according
to EN 62196-1 and SAE-J1772
Type 2 cable: up to 32A / 400V AC according
to EN 62196-1 and VDE-AR-E 2623-2-2
Type 2 standard socket: 32A / 400V AC ac-
cording to EN 62196-1 and VDE-AR-E
2623-2-2
●
-25°C to + 50°C (without direct sunlight)
●
-25°C to + 40°C (without direct sunlight)
-25°C to + 80°C
5 % to 95 % (non condensing)
max. 2000 m above sea level
max. 0.5°C / min
Technical data