9.5­ Calibration
To maintain the specified precision of the measurement results, the instrument
must be recalibrated at regular intervals by our factory service. We recom-
mend a recalibration interval of one year. Send the appliance to the following
address:
Benning Elektrotechnik & Elektronik GmbH & CO. KG
Service Centre
Robert-Bosch-Str. 20
D - 46397 Bocholt
9.6­ Spare­parts
Fuse F 10 A, 500 V, 1.5 kA, D = 6.3 mm, L = 32 mm
0.­ Application­of­rubber­protection­frame
-
Y ou can store the safety measuring lines by winding the safety measuring
lines around the rubber protection frame  and engaging the tips of the
safety measuring lines with protection against the rubber protection frame
 (­see figure 13).
-
Y ou can engage a safety measuring line to the rubber protection frame
, that the measuring tip protrudes freely, in order to be able to apply the
measuring tip - jointly with the BENNING MM 8/ 9/ 10 to a measuring point.
-
T he rear support on the rubber protection frame  provides for an inclined
setup of the BENNING MM 8/ 9/ 10 (­facilitates reading) or attachment (­see
Figure 14).
T he rubber protection frame  is fitted with a lug which can be freely used
for an attachment option.
see figure 13:
see figure 14:
.­ Technical­data­of­the­measuring­accessories
­
4­mm­Safety­measuring­cable­ATL­2
-
S tandard: EN 61010-031,
-
M aximum rated voltage to earth (­ ) and measuring category: 1000 V
CAT III, 600 V CAT IV,
-
M aximum rated current: 10 A,
-
P rotective class II (­  ), continuous double or reinforced insulation,
-
C ontamination class: 2,
-
L ength: 1.4 m, AWG 18,
-
E nvironmental conditions:
Maximum barometric elevation for making measurements: 2000 m,
Temperatures: 0 °C to + 50 °C, humidity 50 % to 80 %
-
O nly use the measuring cables if in perfect condition and according to this
manual, since the protection provided could otherwise be impaired.
-
T hrow the measuring cable out if the insulation is damaged or if there is a
break in the cable/ plug.
-
D o not touch the bare contact tips of the measuring cable. Only grab the
area appropriate for hands!
-
I nsert the angled terminals in the testing or measuring device.
2.­ Environmental­notice
At the end of the product's useful life, please dispose of it at
appropriate collection points provided in your country.
11/ 2006
Winding up of the safety measurement line
Assembly of the BENNING MM 8/ 9/ 10
­ B ENNING­MM­8/­9/­10­
P.no. 749726