C A L I B R A T I N G T H E B L A N K H O L D E R
▷ Activate the
blankholder
E N
The current tool is placed down and the blank
holder [2] moves to the change position.
1
Fig. 3
Removing the extraction hood
1 Extraction hood
2 Blank holder
3 Lever
A Operation button
▷ Release lever [3] of extraction hood [1] and pull
off the extraction hood toward the front.
▷ Loosen fastening screw [1] and pull off the blank
holder 1 toward the right.
1
Fig. 4
Removing the blank holder 1
1 Fastening screw for blank holder
2 Blank holder 1
20
Deposit tool and change
function.
2
A
▷ Clean the locating bore and surfaces.
3.2.3 Inserting the Ceramill blank holder for
rotational milling
▷ Check the connection mandrel of the blank
holder and clean if required.
▷ Insert the Ceramill Roto TI tools into the
Ceramill tool holder for rotational milling with
the tool shank facing outward (see chapter 4.2
on page 28).
▷ Insert the tool holder together with the calibra-
3
tion sleeve via the connection mandrel to the
stop into the locating bore.
Fig. 5
▷ Tighten fastening screw [1] with the torque
wrench until the torque wrench clicks once.
1
2
Fig. 6
Fastening the tool holder 4
1 Fastening screw for tool holder
2 Tool holder 4
▷ Mount the transparent splash guard.
▷ Insert the swarf sieve.
> 0
2
0