4.2 Replacement of the battery module
Safety rules
Batteries constitute a danger (electrical shock, burns). The short-circuit current may be very high. Precautions
must be taken for all handling:
remove all watches, rings, bracelets and any other metal objects;
use tools with insulated handles.
Tower models
Removal of the battery module
This operation may be carried out with the UPS supplying power to the load.
C
A R
L S
io n
P U
lu t
E v o
0 0
1 5
B
A
D
4. Maintenance
A - Unclip the small plate with the MGE
logo on the front panel of the UPS.
B - Remove the two screws.
C - Remove the left-hand side of the front
panel by pulling it slightly up and then
forward.
D - Disconnect the battery module by
pulling apart the connectors (never pull on
the cables).
34007117EN/AB
- Page 23