Descargar Imprimir esta página

Wavetek Meterman HD160B Manual De Instrucciones página 12

Multímetro digital robusto con selección automatica de escala

Publicidad

Idiomas disponibles

Idiomas disponibles

4
0
10
480V
MENU
240V
120V
50V
24V
SAFETY
TESTER
500V AC
MAX
10A
10A
mA
mA
MAX
20A/10sec
FUSED
Fig. 5
The diode test measures the voltage drop across a diode junction.
test leads as shown in figure 5.
Apply probe tip of red lead to the anode and of black lead to the cathode of the
diode.
The meter's display indicates the forward voltage drop (approx. 0.6V for
silicon diode or 0.4V for germanium diode). An open diode is indicated by "I OL".
Reverse test lead connections to the diode to perform a reverse bias test. "I OL"
indicates a good diode. Notes: "I OL" for both reverse and forward bias tests
indicates an open diode. A low voltage reading for both bias tests indicates a
shorted diode. If the diode is shunted by a resistor of 1000 ohms or less, it must
be removed from the circuit before taking the measurement. Bipolar transistor
mV
20
30
40
HD160B
SELECT
CLEAR
OFF
OFF
V
V
2
A
A
V
COM
COM
CAT III
CA
T III
MAX
40mA MAX
1500V
FUSED
1000V
1
DIODE AND CONTINUITY TEST (See Fig. 5)
550 - 900mV
good
DC
Reverse Bias Test
5
Anode
Set the Function/Range switch to
- 11 -
bad
bad
<1V
DC
good
Anode
Cathode
red
Cathode
3
red
Connect the
V
V
Hz
.

Publicidad

loading