3. WORKING WITH THE MACHINE

3.1. Switch on the machine

Before starting the machine take care: long hair, clothes such as ties and jewellery can not
be caught by the rotary wheels.
Turn the main switch to the position I (= On) (see under 2.1)
3.2. Select the operating mode and the paper feeding
In general you can choose from four operating modes:
3.2.1. Folding with counter
3.2.2. Folding with pre-counter (count down function)
3.2.3. Folding of single sheets (see point 2.5 daily mail)
3.2.4
a.
b.
c.
a. Insert the paper to be folded (see point 2.4)
b. Set the fold type (see fold type set-up under point 3.3 and 3.4)
c. Activate the appropriate paper tray(s) (only for the TF MULTI plus)
d. Start the folding process by pushing the Start-Stop button (see
under 2.1)
e. The machine stops if
i. There is no more paper or
ii. You push the start-stop button again.
a. Insert the paper to be folded (see point 2.4)
b. Set the fold type (see fold type set-up under point 3.3 and 3.4)
c. Enter the required quantity by means of the preset buttons. The quantity
is shown on the display (see under 2.1)
(Button 1 = 1000, button 2 = 100, button 3 = 10, button 4 = 1)
(from left to right)
d. Activate the paper tray(s) (only at the TF MULTI plus)
e. Start the folding process by pushing the Start-Stop button. (see
under 2.1)
f. The machine stops if
i. P reset quantity of paper is folded or
ii. There is no paper. In this case please refill the paper tray and push
the start button again or
iii. push the start-stop button again.

Cascade function (only with the TF MULTI plus)

Cascade function stands for an automatic folding of the feeding stations
1, 2 and 3. The sheets are fed from 1 feeding station (e.g. station 1)
until this station is empty. The process will continue from the next station
(e.g. station 2 and 3).
The cascade function can be set per key stroke! For this you press the
"keys of the feeding stations 1 and 2" simultaneously for 2-3
seconds.
To go back to the standard working mode press the two "keys of the
feeding stations 1 and 2" again for 2-3 seconds.