VHW310 - VHW311
Emptying the container
Before proceeding with these operations, turn off the
vacuum cleaner and remove the plug from the power
socket.
If this vacuum cleaner is used to collect hazardous
material, do not attempt to open or empty its contents
without personal protective clothing and respiratory
protection.
This procedure must be completed in a contained
environment.
Contact with the cleaner, filters and all other
accessories used when picking-up hazardous
materials must be handled according to federal
(EPA, OSHA), state and local regulations valid for the
vacuumed substance.
Before emptying the
container,
(see "Shaking the filter" paragraph).
1.
Lid
2.
Vacuum union hose
3.
Lid release levers
4.
Filter chamber and dust container
■
Remove vacuum union hose (2) from the lid (1).
■
Release the lid (1) by using one of the two levers (3) of
the lid (1); then remove it together with the filter.
■
Turn the container (4) counter-clockwise and lift it.
■
Empty the container.
■
Reinstall it by carefully inserting all the pins in the
container base (4), then turn it clockwise to fasten it.
■
Reinstall the lid (1) together with the filter by pressing
until both levers (3) lock, then reconnect the hose (2).
At the end of a cleaning session
■
Turn off the vacuum cleaner and remove the plug from
the socket.
■
Wind the power supply cord.
■
Empty the container as described in the "Emptying
US
the container" paragraph. Clean the vacuum cleaner
as described in the "Maintenance, cleaning and
decontamination" paragraph.
■
Wash the container with clean water if aggressive
substances have been vacuumed.
■
Store the vacuum cleaner in a dry place, out of reach of
unauthorized people.
C392
WARNING!
WARNING!
it is advisable to clean the filter
Figure 8
Maintenance, cleaning and
decontamination
WARNING!
The precautions described below must be taken
during all the maintenance operations, including
cleaning and replacing of the filter.
■ To allow the user to carry out the maintenance
operations, the vacuum cleaner must be
disassembled, cleaned and overhauled as far as
is reasonably possible, without causing hazards
for the maintenance staff or other people. The
suitable precautions include decontamination
before disassembling the device, adequate
filtered ventilation of the exhaust air from the
room in which it is disassembled, cleaning of the
maintenance area and suitable personal protection.
Compartments that are not dust-tight must be opened
with suitable tools (screwdrivers, wrenches, etc.) and
thoroughly cleaned.
■ Carry out a technical inspection at least once a
year, for example: check the filters to find out
whether the air-tightness of the vacuum cleaner
has been impaired in any way and make sure that
the electric control panel operates correctly. This
inspection must be carried out by the manufacturer
or by a competent person.
Primary filter disassembly and replacement
WARNING!
When the vacuum cleaner is used to vacuum
hazardous substances, the filters become
contaminated, therefore:
■ Work with care and avoid spilling the vacuumed
dust and/or material.
■ Place the disassembled and/or replaced filter in a
sealed plastic bag.
■ Seal the bag.
■ Dispose of the filter in accordance with the laws in
force.
WARNING!
Filter replacement is a serious matter. The filter must
be replaced with one of identical filtering surface
characteristics.
Otherwise the vacuum cleaner will not operate
correctly.
8
01/2015