Motor cooling fan inspection and cleaning
Periodically clean the motor cooling fan to prevent the motor
from overheating, especially if the device is used in a dusty
place.
Hose and inlet inspection
1.
Vacuum union hose
2.
Vacuum working hose
Hoses check
Make sure that the vacuum union hose (1) is in a good
condition and correctly fixed.
If the hose is damaged, broken or badly connected to the
unions, it must be replaced.
When sticky materials are treated, check for possible clogging
along the working hose (2), in the inlet and on the deflector
plate inside the container.
Scrape the inlet from the outside and remove the deposited
waste as indicated in the figure.