Measuring your weight and
starting an analysis
Caution: 
Pregnant women and persons with 
implanted medical devices such as pace­
makers must not use these scales.

Important:

To ensure correct measurement, the skin of 
your feet, calves and thighs must not meet.
Only step on the scales with bare feet, 
  o therwise the analysis measurement will not 
work and only the weight will be displayed.
Important:
The scales automatically calibrate when 
switched off.  
To ensure a correct reading, do not move 
the scales after switching off.
The measuring results shown on the scale 
are all individual values and must not be 
added together. Otherwise the total will 
exceed 100%.
Any saved data will not be deleted if the 
battery is changed. Without batteries, the 
time and date are stopped so you may 
have to make corrections after changing 
the battery. Days on which the scale has no 
batteries will not be included in the analysis 
graphic.
The scales automatically identify the users 
based on their weight (deviations of +/­ 5% 
possible). You do not need to turn them on. 
Just step on the scales with bare feet and 
stand still while the symbol 
border around it in the display (figure C). 
Distribute your weight evenly between both 
legs.
Several different situations can occur 
as described here (user detection) for 
  d isplaying the measured values.
The user was identified properly
The display shows the weight and the User 
Profile Number. After about 3 seconds the 
n
cockpit view 
 appears.
10 
D
 is lit up with a 
Information:
If "­­.­" appears in the display instead 
of the values, the measurement was 
unsuccessful.
Please carry out the measuring procedure 
again.
Note: Very dry skin and/or thick calluses 
can produce false results. The measure­
ment will be more accurate if the soles of 
your feet are of a normal skin moisture 
or slightly moist. To keep from slipping, 
however, never use the scales with wet 
feet.
While the cockpit view 
be displayed, you can press the right 
navigation button ► to display graphics for 
30 days of analyses:
o
Weight progression analysis values
FAT
Fat analysis values
N
Muscle mass analysis values
Information:
If gaps appear in the curves, then analyses 
or weight measurements were not carried 
out for one or more days. 
If a user carries out measurements multiple 
times per day, only the last measurement 
will appear. This allows you to correct an 
incorrect measurement.
In addition, you can call up the one or 
ten­year view for each 30 days analysis 
overview by pressing the SET button.
For an annual overview, the average value 
of the previous 15 days of measurements is 
calculated and displayed. For the 10­year 
view the same thing is done in 90­day 
periods.
If M is shown against a dark background, 
you can call up the last 30 values.
  ■ Press the SET button to display the last 
measured value.
  ■ Press the navigation button ◄ to display 
additional values in order of date.