MODIFIABLE PARAMETERS
These settings apply exclusively to the models fitted with Easytronic II Micro power unit.
User menu
With the compressor off, keep the "Function" key pressed for at least 5 seconds.
N°
Parameter
U0
Set loadless pressure (*)
U1
Set loading pressure (**)
U2
Unit of measure (***)
•
to select the parameter desired use START (forward) and RESET (back) keys,
•
then press the FUNCTION key to show the value of the chosen parameter,
•
to change the value use START (to increase) and RESET keys (to decrease),
•
confirm the value set by pressing the FUNCTION key.
•
The power unit returns to the main menu, and after 5 seconds without pressing any key it returns to the standard display.
(*) Set loadless pressure: indicates the value of pressure at which the compressor starts the loadless operating cycle.
(**) Set loading pressure: indicates the value of pressure at which the compressor starts compressing air again.
(***) 1=bar, 0=psi
Assistance menu
The settings below must be performed only by authorised technicians.
With the compressor off or in alarm status, keep the "FUNCTION" and "RESET" buttons pressed for at least 5 seconds, then
a password will be requested.
N°
Parameter
A0
Temperature to power fan
A1
Time loadless
A2
Delay time in stoppage phase
A3
Enable pressure sensor (*)
A4
Enable temperature sensor (*)
A5
Enable automatic start (*)
A6
Enable phase sequence (*)
A7
Expiry oil hours
A8
Expiry oil filter hours
A9
Expiry air filter hours
A10
Expiry oil separator hours
A11
Total hours (**)
A12
Loading hours (**)
(*) 1=enabled, 0=disabled
•
to select the parameter desired use START(forward) and RESET keys (back),
•
then press the FUNCTION key to show the value of the chosen parameter,
•
to change the value use START (to increase) and RESET keys ( to decrease),
•
confirm the value set by pressing the FUNCTION key.
•
The power unit returns to the main menu, and after 5 seconds without pressing any key it returns to the standard
display.
CONTROLS AND SETTINGS
U.M
Bar
Bar
Bar/Psi
U.M
°C
sec.
sec
hours
hours
hours
hours
hours
hours
Min. value
Default value
0.5
10.0
0
8.5
0
1
Min. value
Default value
0
80
30
75
30
60
0
1
0
1
0
0
0
1
0
4000
0
4000
0
2000
0
4000
0
—
0
--
Rotar Micro - Cod.197CC2300 - Rev.01 - 07/2008
Max value
15.0
(Set P loadless) – 0.5
1
Max value
150
900
900
1
1
1
1
65536
65536
65536
65536
65536
65536
9 9 9 9 9
GB