Correct maintenance is crucial to achieve maximum efficiency of your compressor, and to lengthen its operating life.
•
It is also important to comply with the maintenance intervals recommended, but it must be remembered that such
intervals are suggested by the manufacturer in the event that the environmental conditions of use of the compressor are
optimal (see "Installation" chapter).
•
The maintenance intervals can therefore be reduced depending on the environmental conditions in which the compressor
operates.
•
The oil used is RotEnergy Plus, the use of a different oil does not guarantee perfect efficiency and compliance with the
maintenance intervals.
•
The following pages describe the routine maintenance operations which can be performed by the person in charge of
the compressor, the non-routine maintenance operations must instead be performed by an authorised technical assistance
centre.
MAINTENANCE OPERATION
ROUTINE MAINTENANCE
Condensate drain
Check oil and possible top up
Clean filtering element
Check blockage and clean radiator
Check the tension of the transmission belt
Replace the filtering element
Replace oil filter
Replace oil separator filter
Replace oil
NON-ROUTINE MAINTENANCE
Replace one-way drain valve
Review suction valve
Review thermostat valve
Review minimum pressure valve
Replace the transmission belt
Replace solenoid valve
Replace hoses
Replace hoses
Review screw
If the hourly limit is not reached, the maintenance operations highlighted in bold must be performed at least 1 time a year.
• To verify correct machine operation, perform the followng checks after the first 100 hours of work:
1) Check the oil level: top up with the same type of oil if necessary.
2) Check for proper screw tightening: in particular the power electric connection screws.
3) Visually check that all fittings seal properly.
4) Check the belt tension and if necessary, reset it.
5) Check the hours of work and the type of service selected
6)
Check room temperature.
BEFORE MAINTAINING THE MACHINE ALWAYS PERFORM THE FOLLOWING:
¹
Press the machine automatic stop button (do not use the emergency button).
¹
Power the machine off by means of the wall outer switch.
¹
Close the line cock.
¹
Make sure that no compressed air is inside the oil separator tank.
¹
Remove fairing and/ or panels.
12
12
12
12
12
Rotar Micro - Cod.197CC2300 - Rev.01 - 07/2008
OETSYN-Schraub,
MAINTENANCE
Maintenance table
MAINTENANCE INTERVAL
working hours
500
1000
2000
2000
4000
4000
4000
4000
12000
12000
8000
6000
12000
12000
8000
24000
o
-
1 time a month
500
1 time a year
1 time a year
1 time a year
1 time a year
1 time a year
at least
-
-
-
-
-
-
-
-
-
-
-
-