SICE S 62 E Manual De Instrucciones página 201

Equilibradora de banco
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Fitting the external mechanical sensor and relative support
(if available)
- Fasten the external sensor support to the wheel balancer body using the three screws
supplied with the machine (A, fig.5b);
- Insert the external sensor pin (B, fig.5b) in the sensor support bush (C, fig.5b);
- Screw the screw (D, fig.5b) bringing it closer to the sensor pin without touching it;
- Make sure that the external sensor rotates freely;
- Connect one of the sensor's cable connectors to the socket located on the sensor body
(H, fig. 5a);
- Tape the cable to the sensor support (F, fig. 5b) so that it is never tensioned;
- Connect the sensor cable connector to the machine's rear panel (G, fig.5b).
IMPORTANT: after installing the external sensor, calibrate the sensor as described in
the paragraph "Width sensor calibration".
5a
5b
Die wichtigsten Funktionsteile (Abb. 8)
(A) Automatischer Messarm für Durchmesser und Abstand
(B) Automatischer Breitenmessarm (falls vorhanden)
(D) Anzeige-/Steuerpaneel
(E) Flanschträger
(F) Auswuchtgewichtedeckel
(G) Radträgerwelle
(H) Kegelträger
(I)
Löcher für die Bewegung
(L) Feststellbremse für die Radträgerwelle (auf Anfrage)
Betriebsanleitung S 62 E