means must also be taken into account.
Environmental operating conditions must comply with the following requirements:
- relative humidity ranging from 30% to 80% (without condensation);
- temperature ranging from 0° to +50°C.
WARNING
For information concerning the technical features, warnings and maintenance instructions
consult the related operator manuals provided with the documentation of the machine.
CAUTION
The machine must not be operated in potentially explosive atmospheres.
The machine is supplied partially disassembled and is to be assembled according to the
procedures described below.
Fixing the machine to the ground (Fig. 5)
The machine is to be fixed to the ground if:
- It does not have the accessory triangular
foot.
- If it does have the accessory triangular
foot but is going to be used with wheels
heavier than 50Kg. In such a case the
triangular foot will have to be removed
in order to fix the front bracket.
- Undo the three M8x60 hex head screws
fastening the machine to the pallet.
- Remove the plastic washers between
the casing and the three L brackets:
these brackets will be used to fasten the
machine to the floor.
- Refit the brackets on the machine in the original
positions, without tightening the screws.
- Position the machine on the ground in the selected
position and make sure that the surrounding
spaces correspond to the minimum values indi-
cated in Fig. 4.
- Trace the position for drilling on the floor.
- Drill in the traced position and then take the in-
cluded Fischer M8 and insert them into the holes
that were made.
- Secure the machine to the floor by fastening the
L brackets to the Fischer anchor bolts using the
relative screws and washers (fig.5).
- Tighten the three fastener screws to the casing.