2. DESCRIPTION
See Figures a-b:
① ①
JAW SUPPORT
Seat for inserting the pressing jaws. Can be rotated 340° to allow
the operator maximum freedom of position.
② ②
POWER BUTTON
Used to start the motor and activate the pressing cycle. Upon release,
the motor stops immediately, maintaining the pressure reached.
③ ③
18V - 2.0 Ah Lithium-Ion RECHARGEABLE BATTERY
Electronic control of individual cells to prevent overload or underload.
Increased durability and reduced charging time, thanks to AIR COOLED
technology. Timed automatic switch-off for optimal energy consumption.
④ ④
JAW LOCK/RELEASE PIN
To secure the jaws to the pressing tool.
⑤ ⑤
OLED DISPLAY (PUMA-RR and LYNX-RR only):
Activated upon tool start-up and switched off automatically after ap-
proximately 60 s not in use; displays the tool operating parameters;
the home screen can be edited (see part 4).
⑥ ⑥
CAPACITIVE TOUCH BUTTON (PUMA-RR and LYNX-RR only) :
Browses the various menu settings (see part 4); works only with active
display and using a bare, ungloved.
PRESSURE RELEASE/EMERGENCY BUTTON
When held down, the ram returns to the start position, enabling the
jaws to be opened, where necessary, at any moment and irrespective
of the battery charge status.
⑧ ⑧
HIGH EFFICIENCY LED WORKLIGHTS
Allow users to illuminate the work area; switch on automatically
when the start button is pressed and extinguish 25 s after the end of
the cycle.
⑨ ⑨
BATTERY RELEASE
To release and remove the battery from its seat.
⑩ ⑩
GRIP
Enables the tool to be held securely and well-balanced during use;
optimal comfort during handling thanks to its rubber inserts.
⑪ ⑪
SHOULDER STRAP RING
To attach the shoulder strap provided to support the tool while carrying.
3. INSTRUCTIONS FOR USE
The tool is supplied with the battery partially charged; prior to initial
use, it must be recharged according to the instructions in the battery
charger user manual.
It is recommended to always check the battery charge status before use.
To remove the battery from the tool, hold down the release button
and slide the battery forwards (Fig. d).
To insert the battery, slide it backwards until it locks into place (Fig. d).
GB
3.1) Pressing jaw assembly
Remove the battery from the tool before mounting or
replacing the jaws.
Choose the appropriate jaw for the operation to be carried out based
on the profi le and diameter of the joint to be pressed, as indicated in
the instructions provided by the joint manufacturer. Make sure that the
joint is suitable for the diameter and material of the pipe being used.
To achieve a perfect pressfi t, it is essential that the
correct jaw is used for the joint to be pressed. Use of
unsuitable jaws can lead to excessive or insuffi cient pressure,
resulting in the joint being non-watertight and thus unusable.
Press the locking pin and turn it to the right to release it into the fully
open position (Fig. f).
Insert the jaws into the support head until the hole is aligned with the
locking pin.
Push the pin right in and turn it to the left to lock it (Fig. f).
Before starting the tool, make sure the locking pin is
correctly inserted and locked.
A partially locked pin may cause the tool to be damaged!
3.2) Pressing jaw positioning
The jaws can be rotated 340° to allow the operator maximum freedom
of position (Fig. g).
Open the jaws by hand by pressing at the rear top and bottom.
Position the jaws around the joint, ensuring the correct alignment of
the pressing jaw with the joint, closely following the manufacturer's
instructions (Fig. i).
3.3) Pressing procedure
During tool operation, keep your hands away from the
pressing jaws! Failure to comply with this warning can
lead to serious physical injury
Hold the tool fi rmly with both hands, ensuring that the jaws work at
90° to the joint.
Press the power button to start the pressing procedure (Fig. l) and keep
it held down until the motor switches off automatically; the automatic
switch-off of the motor ensures the calibrated pressure has been
reached, to guarantee the necessary pressing force (Fig. m).
After the motor switches off, before releasing the power
button, carry out a visual check to ensure the pressing
jaws have closed completely around the joint. The jaws must
be completely closed to guarantee a correct pressing (Fig. m).
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

PumaLynx-rrLynx