Diagram 2 (Buffer Tank Sensor) - Elledi RODI STEEL Manual De Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Diagram 2 (buffer tank sensor)

Diagram 2 can be used in a system where there is a buffer tank that operates the heating system and, if pre-set, also DHW production. In
this system, the thermo-stove is directly connected to the buffer tank.
In this type of circuit, room temperature is managed by a control unit (not supplied by Elledi) that controls the buffer tank and any zone
valves. The buffer tank temperature is controlled by the thermo-stove through a sensor.
The thermo-stove operates at maximum power to reach the set buffer tank temperature. When it is reached, the stove enters ECO STOP
mode and is automatically restarted if the buffer tank temperature falls below this value. The advantage of using a buffer tank is that, when
the set temperature is reached, it is maintained via the thermo-stove ever-active ECO STOP function. The buffer tank can be connected to
other heat production units, such as solar panels.
Model Rodi Steel Use and Maintenance Manual
Rev.2 31/07/2017
Page58