Description of controls
18:00
20°C
OFF
MENU DESCRIPTION
The thermo-stove is equipped with various functions, available in the programming menus. Some of these menus are accessible to the
user, others are password protected, namely only accessible to the Technical Support Centre.
The available menus are the following:
• CLOCK SETTING menu
• CHRONO SETTING menu
• SELECT LANGUAGE menu
• SEE CALIBRATION menu
• STOVE STATUS menu
• WORKING HOURS menu
• DATA BANK menu
• HOUR RESET menu
• FACTORY CALIBRATION menu
• SELECT RECIPE menu
• SYSTEM LAYOUT menu
• SEASON menu
SYSTEM LAYOUT
This function allows the thermo-stove to be adapted to the type of hydraulic system installed in the building. The available variants are:
DIAGRAM 0 - system direct operation
DIAGRAM 1 - boiler sensor
Please note that the buffer tank is used to build up water for heating systems, the boiler for managing sanitary
system water.
CLOCK ADJUSTMENT (CLOCK SETTING MENU 01)
To adjust the clock, follow the steps below starting from the main menu status:
1. Press and hold the P4 key for 2 seconds until the CLOCK SETTING MENU appears, then confirm with the P6 key.
2. The display shows CLOCK DAY: use the P4 and P5 keys to adjust the current day according to the table below and confirm with
key P6.
3. The display shows CLOCK HOURS and the current hour time is displayed: adjust the hour time via the P4 and P5 keys and
confirm with key P6.
4. The display shows CLOCK MINUTES: use the P4 and P5 keys to adjust minutes and confirm with P6 key.
5. By confirming with the P6 key, you will automatically go back to CLOCK SETTING MENU 01.
LANGUAGE SELECTION (SELECT LANGUAGE MENU 03)
To adjust the language, follow the steps below starting from the main menu status:
1. Press and hold the P4 key for 2 seconds until the CLOCK SETTING MENU appears.
2. Press the P4 key twice: the display will show SELECT LANGUAGE MENU. 3. Access via the P6 key: the display shows the
selected language.
4. Select the desired language with the P4 and P5 keys and confirm with P6 key.
Model Rodi Steel Use and Maintenance Manual
40°C
(password protected)
(password protected)
(password protected)
(password protected)
(password protected)
Wording
01
02
03
04
05
06
07
OFF
P1 : button to decrease programming values
P2 : button to increase programming values
P3: switch-on and switch-off button
P4 : button to display and decrease a setting
room thermostat / prolonged pressure to access
the menu
P5 : button to increase a room thermostat
setting
P6 : button to view the water temperature
(P4 and P5 to change its value) and multi-function
P7 : with no function in this version of thermo-stove
DIAGRAM 2 - buffer tank sensor
DIAGRAM 3 - boiler sensor + buffer tank sensor
Screen display
Day Monday
Day Tuesday
Day Wednesday
Day Thursday
Day Friday
Day Saturday
Day Sunday
Excluded Day
Rev.2 31/07/2017