Technical Specifications - Microlife NC150 BT Manual De Instrucciones

Tabla de contenido

Publicidad

®
• The Bluetooth
icon indicator AK flashes, when connecting with
a device or uploading data to the device.
®
• The Bluetooth
function is automatically switched off during
measurement; after measurement the device will switch it on
and upload the data to the «Microlife Connected Health+» App.
App Tutorial
To access the tutorial, select «Tutorial» in the menu of the «Microlife
Connected Health+» App (located in the upper left corner on the
screen).
11. Error Messages
• Measured temperature too high AS: Displays «H» when
measured temperature is higher than 42.2 °C / 108.0 °F in
body mode or 100 °C / 212 °F in object mode.
• Measured temperature too low BT: Displays «L» when
measured temperature is lower than 34.0 °C / 93.2 °F in body
mode or 0 °C / 32 °F in object mode.
• Ambient temperature too high BK: Displays «H» and
when ambient temperature is higher than 40.0 °C / 104.0 °F.
• Ambient temperature too low BL: Displays «L» and
ambient temperature is lower than 15.0 °C / 59.0 °F in body
mode or lower than 5.0 °C / 41.0 °F in object mode.
• Error function display BM: The system has a malfunction.
• Blank display BN: Check if the batteries have been inserted
correctly. Also check polarity (<+> and <->) of the batteries.
• Flat battery indicator BO: If only «» icon is shown on the
display, the batteries should be replaced immediately.
12. Cleaning and Disinfecting
Use an alcohol swab or cotton tissue moistened with alcohol (70%
Isopropyl) to clean the thermometer casing and the measuring
sensor. Ensure that no liquid enters the interior of the device. Never
use abrasive cleaning agents, thinners or benzene for cleaning and
never immerse the device in water or other cleaning liquids. Take
care not to scratch the surface of the sensor lens and the display.
13. Battery Replacement
This device is supplied with 2 new, long-life 1.5V, size AAA
batteries. Batteries need replacing when this icon «» BO is the
only symbol shown on the display.
Remove the battery cover BR by sliding it in the direction shown.
5
Replace the batteries – ensure correct polarity as shown by the
symbols in the compartment.
Batteries and electronic devices must be disposed of in
accordance with the locally applicable regulations, not with
domestic waste.
14. Guarantee
This device is covered by a 5 year guarantee from the date of
purchase. The guarantee is valid only on presentation of the guar-
antee card completed by the dealer (see back) confirming date of
purchase or the receipt.
• The guarantee covers the device. Batteries and packaging are
not included.
• Opening or altering the device invalidates the guarantee.
• The guarantee does not cover damage caused by improper
handling, discharged batteries, accidents or non-compliance
with the operating instructions.
Please contact Microlife-service.

15. Technical Specifications

when
Type:
Non Contact Thermometer NC 150 BT
Measurement
Body mode: 34.0 - 42.2 °C / 93.2 - 108.0 °F
range:
Object mode: 0 - 100.0 °C / 32 - 212.0 °F
Resolution:
0.1 °C / °F
Measurement
Body mode:
±0.2 °C, 35.0 ∼ 42.0 °C / ±0.4 °F, 95.0 ∼ 107.6 °F
accuracy
(Laboratory):
±0.3 °C, 34.0 ∼ 34.9 °C and 42.1 ∼ 43.0 °C /
±0.5 °F, 93.2 ~ 94.8 °F and 107.8 ~ 109.4 °F
Object mode:
±1.0 °C, 0 ∼ 100.0 °C / ±2 °F, 32.0 ∼ 212 °F
Display:
Liquid Crystal Display, 4 digits plus special icons
Acoustic:
The unit is turned ON and ready for the measure-
ment: 1 short beep.
Complete the measurement: 1 long beep (1 sec.) if
the reading is less than 37.5 °C / 99.5 °F, 10 short
«beep» sounds, if the reading is equal to or greater
than 37.5 °C / 99.5 °F.
System error or malfunction: 3 short «bi» sounds.
Memory:
30 readings recall in the memory mode with a
record of both time and date.

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido