5. InsTRUCTIons foR UsE
aTTEnTIon: Allow the pipettor to remain in the charging stand for 12 hours to fully charge the battery if the battery is new or has been allowed to
fully discharge.
1.
Connecting the Transformer
• Ensure that voltage rating of the transformer correctly corresponds to the voltage from the electrical outlet.
• Do not use electrical outlets that are timed or switched.
• Use only the transformer provided with the unit or an approved replacement from 3M.
• Connect the transformer into the connector jack at the rear of the charging stand's base.
• Plug the transformer into an AC electrical outlet. When charging, the battery symbol will be displayed with the +/- symbols flashing in the
pipettor's display.
• When the battery is full the battery symbol disappears from the display. If the display shows REsET or PREss TIP, press the tip ejection button to
reset the pipettor. The pipettor will then be ready for use.
Pipettor Controls
These controls are often referred to in this manual.
Keyboard
select
- Changes aspiration and dispense speeds.
operating buttons:
start button
- Triggers all piston movements.
2.
arrow up/down
- Shifts to the next mode.
- Increases and decreases the open volume or
speed.
Tip ejection buttons
- Press twice to remove tip.
4
(English)
3.
Enter
- Confirms mode, speed or volume changes.
Reset
- Press to reset the pipettor.
4.