Aventics R412004397 Instrucciones De Servicio página 53

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 159
AVENTICS | Position Controller | R412004397–BDL–001–AC
If the piston cannot reach the position or range, as e.g. the
working pressure has been switched off, this will result in
increased valve wear.
W
Always also witch off the power supply after the working
pressure has been turned off.
W
If necessary, install a pressure switch in the air supply for
the positioning cylinder.
The friction characteristics of the cylinder and the driven
system influence the positioning precision.
Design and applications
53

Publicidad

Tabla de contenido
loading

Tabla de contenido