Troubleshooting • Repair Parts
Symptom
Pump won't start or run.
Blown fuse or breaker.
Low line voltage.
Defective motor.
Defective float switch.
Float obstructed.
Pump starts and stops
Backflow of water from piping.
too often.
Faulty float switch.
Pump won't shut off.
Defective float switch.
Restricted discharge
(obstacle in piping).
Float obstructed.
Pump operates but
Low line voltage.
delivers little or no water.
Worn or plugged impeller.
Anti airlock vent hole is plugged.
Key No.
1
2
3
4
* Replacement vertical switch must be mounted on discharge pipe.
** If the motor fails, replace the pump.
2905-04
2955-04
4
For parts or assistance, call Simer Customer Service at
Probable Cause(s)
Repair Parts List
Part Description
Qty.
Power Cord
1
Cover, Motor Assembly
1
Inlet Screen
1
Switch Assembly
1
1
2
3
5916 0109
Corrective Action
If blown, replace with fuse of proper size or reset breaker.
If voltage under recommended minimum, check size of wiring from
main switch on property. If OK, contact power company or hydro authority.
Replace pump.
Replace float switch.
Remove obstruction.
Install or replace check-valve.
Replace float switch.
Replace float switch.
Remove pump and clean pump and piping.
Remove obstruction.
If voltage under recommended minimum, check size of wiring from main
switch on property. If OK, contact power company or hydro authority.
Replace pump.
Clean out the vent hole with a hat pin or pipe cleaner.