8.2.3 Settings in the menu

During operation of the single pump's display, the following menus appear in
succession:
• Single pump operation:
Setting during initial commissioning / menu sequence during normal operation
(horizontal display)
LC display
The basic setting is displayed again if no setting is made in the subsequent menu
within 30 seconds
72
Setting
When the module is switched on, all symbols
appear on the display for 2 s.
Then, the current setting
Current (basic) setting
(factory setting):
H 5,0 m
.
is applied.
• e.g. nominal delivery head Hs = 5.0 m
and ½ H
(factory setting depends
max
on the pump type)
• Δp-v control mode
• Pump runs in control mode, setback
operation disabled
(see also menu item
• missing = single pump
Turn the control button to adjust the
differential pressure setpoint. The new
differential pressure setpoint flashes.
The new setting is saved by briefly
pressing the button.
The flashing differential pressure set-
point previously set is reset to the previ-
ous value if the button is not pressed
within 30 seconds.
Press control button > 1 second.
The next meu item
).
appears.
Pompes Salmson 05/2015