3.2.2
Adjustment of Control Parameters in the Second Operating Phase
Press the UP and DOWN keys (8/9) simultaneously for at least 4 seconds to
access a list of control parameters (beginning with P1). Pressing the UP key
(8) scans the list upwards and the DOWN key (9) downwards.
The value of the corresponding parameter is displayed when the SET key
(10) is pressed. Press the UP or DOWN key in addition in order to set the
value. Release all the keys to store the new value. The original settings are
restored if no key is pressed for more than 60 seconds.
Parameter
P1
P2
P11
P12
P13
P14
P19
P19 Keyboard Disabling
Keyboard disabling enables the operating keys to be locked. In the locked
position it is not possible to change the set value with the keys. If an attempt
is made to adjust the set value despite keyboard disabling, the display shows
the message „-".
Functional specification
Lowering set point
Waiting time until lowered
Elapsed time indicator,
„units digit"
Elapsed time indicator,
„thousands digit"
Number of releases,
„units digit"
Number of releases,
„thousands digit"
Keyboard disabled
(Set point adjustment
disabled)
13
Operation
Setting range
not adjustable
not adjustable
0: not disabled
1: disabled
Default
setting
-
-
0