Scope Of Delivery; Accessories - salmson IXENS Serie Instalacion Y Puesta En Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

English
Property
Insulation class
Protection class
Electromagnetic compatibility
Emitted interference in acc. with
Interference resistance in acc. with
Sound-pressure level
2)
Permissible fluids
Electrical connection
Internal electric circuit
Speed control
Relative humidity
- at T
= 30 °C
environment
- at T
= 40 °C
environment
1)
Average value of the sound-pressure level at a spatially rectangular measuring surface at a distance of 1 m from the pump surface in accordance with
DIN EN ISO 3744.
2)
For more information about permissible fluids, see the "Fluids" section on the next page.
Tab. 1: Technical data
Fluids
5.3

Scope of delivery

5.4

Accessories

74
Value
F
IP 55
EN 61800-3
EN 61800-3
1)
L
Heating water according to VDI 2035
Cooling/cold water
Water/glycol mixture up to 40% vol.
Heat transfer oil
Other fluids
3~380 V - 3~480 V (±10%), 50/60 Hz
PELV, galvanically isolated
Built-in frequency converter
< 90%, non-condensing
< 60%, non-condensing
• The fluid must be sediment-free.
• Salmson's approval must be obtained for the use of other fluids.
• Mixtures with a proportion of glycol of > 10% influence the Δp-v
• In systems built according to the state of the art, it can be assumed
• Ixens/Ixens Bloc pump
• Installation and operating instructions
• Ixens:
• Ixens Bloc:
• Installation aid for mechanical seal (incl. mounting bolts)
< 74 dB(A) | ref. 20 μPa
pA, 1m
If water/glycol mixtures are used (or fluids with a viscosity other than
that of pure water), an increase in power consumption of the pump is
to be taken into account. Only use mixtures with corrosion inhibitors.
The respective manufacturer's instructions are to be observed!
pump curve and the flow calculation.
under normal system conditions that the standard seal/standard
mechanical seal is compatible with the fluid. Special circumstances
(e.g. solid material, oils or EPDM-corrosive substances in the fluid, air
in the system etc.) may require special seals.
NOTE:
The flow value shown on the IR-Monitor/IR-Stick display or output to
the building management system must not be used to control the
pump. This value is merely an indicator of general trends.
A flow value is not output on every type of pump.
NOTE:
Always read and follow the material safety data sheet for the fluid
being pumped!
Accessories must be ordered separately:
3 mounting brackets with fixation material for installation on a base
2 mounting brackets with fixation material for installation on a base
Remarks
Residential
Industrial
Depending on pump type
Standard version
Standard version
Standard version
Only for special version
Only for special version
Supported mains types:
TN, TT, IT
Salmson 05/2015

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ixens bloc serie

Tabla de contenido