Allocation Of Clamps For System 3; Allocation Of Clamps For System 4 - Sonnenkraft SKSC2HE Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

1.4.3. Allocation of clamps for system 3

Arr 3
PWM/0-10V
VFD
S1
R1
VFD/TRL

1.4.4. Allocation of clamps for system 4

Arr 4
PWM/0-10V
VFD
S1
R1
R2
VFD/TRL
38
VBus
9 10
(optional)
S3
R2
S2
VBus
9 10
S4
S3
S2
Solar system and after-heating with 1 store,
3 (optionally 4) sensors and 2 pumps (for solar
heating and after-heating) as well as an optional
0-10 V control of the boiler. The sensor VFD/TRF
can optionally be used for heat quantity meas-
urement. Sensor S1 is used as the flow sensor
SVL.
Symbol
S1
S2
S3
S4
VFD/
TRF
S4
R1
PWM1
R2
0-10 V
Solar system and store charge in layers with
1 store, 3 sensors, 1 solar pump and 1 3-way-
valve for store charge in layers. The sensors S4/
TFL and VFD/TRF can optionally be used for heat
quantity measurement. In systems without a
VFD sensor, heat quantity measurement can be
carried out using the sensors S4/TRF and S1/TFL.
Symbol
S1
S2
S3
S4/TFL
VFD/
TRF
R1
PWM1
R2
GB
Specification
collector sensor
store sensor lower
store sensor at the top
boiler sensor (optionally)
return sensor for heat
quantity measurement
(optionally)
solar pump
control signl for HE
pump
pump for heat
exchange
control signal for boiler
modulation (optionally)
Specification
collector sensor
store sensor lower
store sensor at the top
flow sensor for heat
quantity measurement
(optionally)
return sensor for heat
quantity measurement
(optionally)
solar pump
control signl for HE
pump
3-way-valve