Kemper autoflow XP Manual De Instrucciones página 33

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 83
Operating device on the blower unit:
1. Operating buttons
• ON (+) Hold for approx. two seconds to turn on the blower unit.
• OFF (-) Hold for approx. five seconds to turn off the blower unit.
2. Filter saturation display
• Increasing filter saturation is indicated via an LED bar. If all four LEDs light up then you can
continue to work with the KEMPER autoflow XP
However, if a warning tone sounds at the same time then the filter must be replaced
immediately because the minimum nominal volume flow is no longer guaranteed. Further use
under these conditions causes health-related injuries because there is no longer enough
overpressure in the protective screen and harmful substances may get into the user's
respiratory zone. The work area must be vacated immediately! It is recommended to change
the particle filter if all four LEDs on the filter saturation display light up.
3. Battery capacity
4 x green LED
3 x green LED
2 x green LED
1 x green LED
1 x red LED
1 x red LED, warning
The battery capacities are approximate values and depend on the condition of the battery used.
It is recommended to charge or replace the battery immediately when battery capacity is 5%.
4
3
2
Image 2.3-1 – Control Elements on the Blower Unit
100% battery capacity
80% battery capacity
60% battery capacity
40% battery capacity
20% battery capacity
5% battery capacity
1
blower respirator system for a short period.
®
EN
33

Publicidad

Tabla de contenido
loading

Productos relacionados para Kemper autoflow XP

Tabla de contenido