Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 83
4. Air flow display
• While the blower unit is turned on, airflow can be individually set on four levels
via the ON/OFF or +/- buttons:
(4 x green LED)
(3 x green LED)
(2 x green LED)
(1 x green LED)
Please note that battery and filter life decrease as airflow increases. This also depends
on the dust exposure in the area with harmful substances.
Filter Replacement:
• Carefully remove the lock (Pos. 1) on the filter cover and in the process remove
the filter cover (Pos. 2) and the filter (Pos. 4) from the blower unit (Pos. 3).
Remove the particle filter (Pos. 4) and replace it with a new one. (if necessary, the prefilter
should also be replaced).
• Put the filter cover (Pos. 2) and the filter back into place (Pos. 4) in the blower unit (Pos. 3)
in reverse order. Verify that the blower unit is properly functioning as described in Section 2.2
„Inspection Before Use".
Note:
• Only original particle filters approved and tested for the KEMPER autoflow XP
may be used.
• Also note the information on the particle filter regarding storage times, best-before date.
34
2
approx 210 l/min
approx 195 l/min
approx 185 l/min
approx 170 l/min
3
1
4
Image 2.3-2 – Filter Replacement
®