eng
The correct power tool will do the job better and safer at the rate for which it was
designed.
b) Do not use the power tool if the switch does not turn it on and off. Any power
tool that cannot be controlled with the switch is dangerous and must be repaired.
c) Disconnect the plug from the power source before making any adjustments,
changing accessories, or storing power tools. Such preventive safety meas-
ures reduce the risk of starting the power tool accidentally.
d) Store idle power tools out of the reach of children and do not allow persons
unfamiliar with the power tool or these instructions to operate the power
tool. Power tools are dangerous in the hands of untrained users.
e) Maintain power tools. Check for misalignment or binding of moving parts,
breakage of parts and any other condition that may affect the power tools
operation. If damaged, have the power tool repaired by a qualified expert
or by an authorised REMS after-sales service facility before use. Many
accidents are caused by poorly maintained power tools.
f) Keep cutting tools sharp and clean. Properly maintained cutting tools with
sharp cutting edges are less likely to bind and are easier to control.
g) Secure the workpiece. Use clamps or a vice to hold the workpiece. This is safer
than holding it with your hand, and also it frees both hands to operate the equipment.
h) Use the power tool, accessories and tool bits etc., in accordance with these
instructions and in the manner intended for the particular type of power
tool, taking into account the working conditions and the work to be performed.
Use of the power tool for operations different from those intended could result in
a hazardous situation. All unauthorised modifications to the power tool are
prohibited for safety reasons.
E) Battery tool use and care
a) Ensure the switch is in the off position before inserting battery pack. Inserting
the battery pack into power tools that have the switch on invites accidents.
b) Recharge only with the charger specified by the manufacturer. A charger
that is suitable for one type of battery may create a risk of fire when used with
another battery pack.
c) Use battery tools only with specifically designated battery packs. Use of
any other battery packs may create a risk of injury and fire.
d) When battery pack is not in use, keep it away from other metal objects like
paper clips, coins, keys, nails, screws, or other small metal objects that
can make a connection from one terminal to another. Shorting the battery
terminals may cause bums or a fire.
e) Under abusive conditions, liquid may be ejected from the battery, avoid
contact. If contact accidentally occurs, flush with water. If liquid contacts
eyes, additionally seek medical help. Liquid ejected from the battery may
cause irritation or bums.
f) Do not use the battery/charger at battery/charger temperatures or ambient
temperatures of ≤ 5°C/40°F or ≥ 40°C/105°F.
g) Do not dispose of defective batteries in the normal domestic waste. Take
them to an authorised REMS after-sales service facility or to a reputed
waste disposal company.
F) Service
a) Have your power tool serviced by a qualified repair person using only
identical replacement parts. This will ensure that the safety of the power tool
is maintained.
b) Comply with maintenance instructions and instructions on tool replace-
ments.
c) Check mains lead of power tool regularly and have it replaced by a qualified
expert or an authorised REMS after-sales service facility in case of damage.
Check extension cable regularly and replace it when damaged.

Specific Safety Instructions

● Avoid mechanical stress to the device. Do not shake or drop the device. Pressure
on the display can damage the device.
● Do not expose the device to temperatures > 60°C; protect against direct sunlight
and heaters.
● Protect the device against moisture; only the camera and the camera cable are
watertight.

1. Technical Data

The REMS CamScope endoscope camera is used for the inspection and
damage analysis of locations with difficullt access such as cavities, shafts,
pipes etc. and serves for documenting the inspection results in the form of
photos and videos. REMS CamScope is protected against occasional submer-
gence in water (≤ 30 min, ≤ 0,1 bar).
1.1. Scope of Delivery
Controller unit
Handheld unit
Camera cable set Color 16-1
Voltage supply / charger Li-Ion
Accessory kit 16-1: Add-on mirror, add-on hook, add-on magnet
USB cable
Video cable
4 batteries 1.5 V, AA, LR6
MicroSD card
Case
1.2. Accessories
Camera cable set Color 9-1
900 mm push cable extension
Accessory kit 9-1: Add-on mirror, add-on hook, add-on magnet
1.3. Handheld unit
Image sensor
Number of pixels
Viewing angle
Transmission frequency
Min. lighting
Modulation type
Bandwidth
Radio transmission range up to 10 m
Power supply
Dimensions
Weight
Camera diameter
Camera protection type
1.4. Controller unit
Display
Pixels
Video system
Reception frequencies
Power supply
External supply voltage
Video level
Video rate
Frame rate
Dimensions
Weight
Temperature range
Humidity
2. Start-up
Remove the screw from the battery compartment (17) of the handheld unit (5),
push the cover in the direction of the arrow to remove, remove the battery
holder, insert 4 1.5 V, AA, LR6 batteries into the battery holder, push the battery
holder back into the battery compartment, slide in the cover, screw in the screw.
Always change all four batteries at once.
Push the controller unit (7) onto the handheld unit (5) from above until it snaps
into place. When inserting the camera cable set (2), make sure that the pin on
the cable plug (3) is pushed into the slit in the cable socket on the handheld
unit (5). Tighten the knurled nut.
The controller unit has an integrated Li-Ion battery. The battery charging time
is approximately 3 hours. A full charge lasts for about 2 hours of operation. The
controller unit can also be operated with the connected supply voltage / charger.
The controller unit can be operated both by radio signal and directly with the
handheld unit.
The enclosed 16-1 accessory kit only fits the 16-1 color camera. A separate
accessory kit is available for the 9-1 color camera. The add-on mirror, add-on
hook and add-on magnet tools are clipped optionally to the camera head.
Always close the cap otherwise the tool could be lost.
2.1. Switching On the Endoscope Camera
Switch on the handheld unit (5) by turning the on/off thumbwheel (4). The
Power-LED (6) lights red. Switch on the controller unit (7) with the on/off button
(8). The on indicator (18) lights green.
2.2. Inserting the MicroSD Card
Insert the MicroSD card in the card slot (15). The card snaps into place. To
remove the MicroSD card, press it again and it springs out.
A MicroSD card is inserted
The MicroSD card is full
 No MicroSD card is inserted
2.3. Controller Unit Settings
The controller unit has a menu in which different settings can be made, e.g.
language, frame rate, memory formatting.
● Keep the menu button (11) pressed for approx. 2 s to go to System Settings.
● Press the OK button and set the desired language first.
● Select the desired flag with the
Navigation in the menu:
175101
buttons: Select a menu entry
175102
OK button:
Confirm selection
175103
button:
Previous menu item, cancel, exit menu
175120
● Structure of the main menu:
175121
175123
175124
175125
175126
175127
175104
16 mm camera
9 mm camera
CMOS
CMOS
704 x 576 (PAL)
640 x 480
50°
45°
2,468 MHz
2,468 MHz
0 lux
0 lux
FM
FM
18 MHz
18 MHz
up to 10 m
4x AA batteries
4x AA batteries
186 x 145 x 41 mm
186 x 145 x 41 mm
(cordless)
450 g
450 g
16 mm
9 mm
IP 67
IP 67
3.5" Color TFT-LCD
320 x 240
PAL / NTSC
2,414, 2,432, 2,450, 2,468 MHz
integrated Li-Ion battery 3.7 V, 1.2 Ah
5 V / 500 mA
0,9 – 1.3 Vpp on 75 Ohm
27 MB per minute
up to 30 frames per second
100 x 70 x 25 mm
140 g
-10°C – +50°C/+14°F – +122°F
15 – 85% RH
buttons and confirm with the OK button.
System Settings: Select Language, Video System,
Format Memory, Default Setup, Software version of
the monitor
eng