INSTALLATION
Drill the holes for the attachment of the metal fixtures
48
Installation manual
1 Position the template (1) supplied with the operator,
ensuring the lower edge of the template coincides
with the base of the hanging style (2) on the interior
side of the gate.
2 Bore the orifices (3) where the bottom post plate will
be attached.
Use 6.5 mm broach.
3 Make an orifice (4) of 21 mm in diameter in order to
make the cylinder key accessible (only in models
MAS210F and MAS250F).
4 Repeat points 1, 2 and 3 on the outside of the gate.
5 Position the template (1) supplied with the operator,
ensuring the upper edge of the template coincides
with the top of the hanging style (2) on the interior
side of the gate.
6 Bore the orifices (3) where the upper profile support
will be attached.
Use 6.5 mm broach.
7 Repeat points 5 and 6 on the outside of the hanging
style.