16
Cleaning / maintenance
16.01 Drainage valve
Cleaning / maintenance
To protect the whirlpump from impurities, a fi lter is integrated in the
drain. When inserting the drainage valve, ensure that the lower pin
is exactly centred in the hole foreseen. The position of the overfl ow
regulator indicates whether the drain is open or closed.
The integrated sieve in the drainage valve must be
cleaned regularly.
A blocked fi lter impairs the suction power of the whirl
pump and consequently the performance.
Faulty functioning results!
16.02 Venturi nozzle units Deluxe
The nozzles must be dismantled and cleaned when water starts to spray from the nozzle while the cleaning program is
running. It is normal for water drops to exit during the cleaning program. This is unavoidable due to the smooth running
design of the interior components.
To remove the nozzle unit
2
nozzle unit
can be removed by applying pressure and turning the key anti-clockwise (to the left).
2
The Venturi unit/injector
can be removed from the nozzle housing using the narrow side of the nozzle key
3
removing the nozzle unit, check whether foreign bodies or lime deposits are the cause of the leak. Parts with lime
deposits can be cleaned with an acid, lime-dissolving substance (e.g. diluted vinegar).
1
Nozzle key
1
Cover ring with nozzle unit
2
Venturi unit/injector with sealing ring
3
When assembling the parts, ensure that they fi t together properly.
When mounting the Venturi unit/injector
Lubricate the injector threads with silicone grease; tighten the Venturi unit/injector by hand as far as
possible, then use the nozzle key to turn the Venturi unit/injector a further 45°! Position the nozzle
unit
carefully in the inner threads of the nozzle housing. Tighten as far as possible and secure.
2
Damaged parts can be replaced by quoting the pertinent Ident. numbers with order.
completely, place the friction surface of the nozzle key
2
HOESCH item no. 117520
HOESCH item no. 11750201 ... (colour)
HOESCH item no. 117508
, ensure that the seal is in the correct position.
3
HOESCH item no. 129396
on the cover ring. The entire
1
2
. After
1
1
3
45°
37