Connecting an external button (230 V/50 Hz) ( Figure m ) ...
... for the subsequent adjustment the limit stops
13
(a)
(b)
(c)
Using the setting wire
The setting wire (j) is used to transfer the motor set button (11) function to the
outside. If the setting wire (j) is connected to an external button (see above), this
external button can be used as a set button for adjusting the limit stops.
Guide the setting wire (j) of the motor cable (15) to the respective switch (e.g.
to the switch box).
(22)
Connecting a corded switch-setting device ( Figure n )
14
54
(j)
(i)
(h)
(d)
(e) (f)
(g)
(k)
Plunger
Key
(a) =
Set button (11)
(b) =
Control device (e.g. single-pole switch/button)
(c) =
Main 230 V/50 Hz
(d) =
Switch box
Terminal configuration
(e) =
PE
green/yellow
(f) =
N
blue
(g) =
L1
black
(h) =
(▲) black
(i) =
(▼) brown
(j) =
white (Setting wire)
(k) =
external button
IMPORTANT
Disconnect the external button again once the limit stops have been adjusted and connect the setting wire (j)
to the neutral conductor (f), see figure k .
Using the setting wire (j) when installing the device for the first time
When installed for the very first time, the roller shutter fitter can connect the entire
motor supply cable (15) to a switch setting device (22) which can then be used to
adjust the tubular motor limit stops.
Using the setting wire (j) to change the limit stops retrospectively:
If you want to change the limit stops of an existing roller shutter installation, all your
electrician needs to do is to connect the setting wire (j) to a conventional external
switch (230 V/50 Hz) in accordance with the connection diagram m. This switch
can then be used in conjunction with your shutter control device to change the limit stops.
Using the setting wire (j) after having adjusted the limit stops:
Once the limit stops have been adjusted, the relevant external switching device
must be disconnected and the motor must be connected again in accordance with
the connection diagram, see figure k.
IMPORTANT
The setting wire (j) must be connected to the neutral conductor (f)
once the limit stops have been adjusted.
Open the terminal contacts by pressing the plungers and connect
1.
all of the tubular motor cable (15) cores according to their functions,
see figure j .
EN