Flat head 1/8" wide screw driver.
(4 mm)
Make sure to replace the
wires on top as shown
in the picture.
- Carefully loosen the spring holders 5 in the outer ends in order to loosen the ceramic ends of the IR tubes.
- Turn the tube in the direction shown in the drawing until the tube is released from the middle spring holders 6 .
Handle broken tubes very carefully to prevent anyone getting hurt.
Dispose of the IR tubes appropriately.
-
A new IR-tube is inserted in the opposite order from the steps above (6-1).
- Carefully insert and turn the tube into the spring holders in the middle 6 .
- Carefully fasten the outer spring holders 5 on the ceramic ends of the tube.
- Attach the cables to the connection plinths 4 and tighten the screws firmly, but not so hard that they break.
- Make sure the cables are firmly fastened in the right way according to the picture.
- Refasten the reflector flanges 3 , the safety grid 2 and retighten the screws 1 on each end.
Turn the machine on and test warm it with the heating area turned upwards.
The tubes shall have an even soft red/orange color tone.
If you have changed only one tube, a small color difference might occur.

IMPORTANT!

Always use original tubes designed for this model of Speedheater IR Paint Remover.
If you do not have the proper competence for this kind of activity, talk to a professional
or the store where you bought the machine.