Dalla Corte DC PRO Manual De Usuario página 51

Ocultar thumbs Ver también para DC PRO:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ALC 02
This alarm concerns group 2
ALC 03
This alarm concerns group 3
ALT 01
This alarm triggers three minutes after pressing
the manual free doses button of group 1 without
switching it off.
PROBABLE CAUSES ARE:
• User's negligence
CONSEQUENCES:
• Anomaly is signaled and dispensing locked.
To cancel the alarm, press the CANC button below
the display
ALT 02
This alarm concerns group 2
ALT 03
This alarm concerns group 3
ALM 01
This alarms triggers when the pre-set number of
cycles of group 1 solenoid valve is reached.
To cancel the alarm, press the CANC button below
the display
ALM 02
This alarm concerns the cycle counter of group 2
solenoid valve
ALM 03
This alarm concerns the cycle counter of group 3
solenoid valve
ALM 05
This alarm concerns the cycle counter of the pump
* These alarms can be triggered only if the serial port they refer to is in use.
ALM 06
This alarm concerns the cycle counter of the auto-
fill solenoid valve
ALM 07
This alarm concerns the cycle counter of the tea
solenoid valve
ALM 08
This alarm concerns the cycle counter of the MCS
solenoid valve
AL SER 01
No serial connection between electronic display
board and power card
AL SER 02*
No serial connection between machin and grinder
AL SER 03*
No serial connection between machine and cash
register interface
AL SER 04*
No serial connection between machine and modem
51

Publicidad

Tabla de contenido
loading

Tabla de contenido