Descargar Imprimir esta página

Set Up And Adjustments - Corghi ERCO 500 Manual De Uso

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

7.8
CHECKS AND INSPECTIONS
7.8.1 MECHANICAL CHECKS
 grease sliding seats of blocks placed under platforms and on bases;
 lift fixing to the ground with 8 anchor bolts (min. recommended size ø = 16 mm)
 clean all parts of the machine;
7.8.2 ELECTRICAL CHECKS
 connections as per diagrams;
 lift grounding;
7.8.3 HYDRAULIC SYSTEM CHECK
 proper oil level in the tank;
 no leakage and blow-by,
 cylinder operation
7.9

SET UP AND ADJUSTMENTS

7.9.1 LOAD LESS CHECK
Carry out two or three complete cycles of lowering and lifting and check:
 the lift for reaching its maximum height;
 the max height limit switch for proper operation;
 the horn/signaling light for proper operation during the final travel;
7.9.2 CHECK WITH LOAD
Repeat checks provided for by 7.9.1 section with the vehicle loaded;
In this case some irregularities can occur; so considering that all adjustments shown are factory-
made, the following can be carried out as an exception:
7.9.3 BOLTS AND NUTS CHECK
After carrying out the checks with load, make a visual inspection of the machine and check bolts
and nuts for proper tightening.
68
WARNING: please follow carefully the
instructions in the coming paragraph for
avoiding damages on the lift.

Hide quick links:

Publicidad

loading

Este manual también es adecuado para:

Erco 500fErco 505Erco 505f