Replacing the Gears

1. Follow steps 1-11 in Replacing the Motor Assembly (section
11.2) to remove the motor and control panel.
2. Inspect the armature gear (Fig. 15, Item 1) on the end of the
motor for damage or excessive wear. If the gear is completely
worn out, replace the motor assembly.
3. Remove and inspect the 1st stage gear (2) and 2nd stage
gear (3) assemblies for damage or excessive wear. Replace, if
necessary.
4. Inspect the front gear box (4) assembly for damage or
excessive wear. If damaged or worn, replace the front gear
box assembly.
i
Clean and refill the gear box cavity up to the rear
face of each gear with Lubriplate (P/N 314-171).
5. Reinstall the motor into the gearbox housing (4).
6. Follow steps 13-24 in Replacing the Motor Assembly
(section 11.2) to replace the motor and control panel.
3
4
11.4

Replacing the Transducer

1. Unplug the unit.
2. Loosen and remove the two filter assembly bolts (Fig. 16, Item
1). Slide the filter assembly from the cart.
1
Performance Series 1650e
1
2
GB
3. Loosen and remove the two motor shroud screws (Fig. 17,
Item 1). Remove the motor shroud (2).
4. Loosen and remove the two motor cover screws (3). Remove
the motor cover (4).
5. Disconnect the transducer wire from the motor controller (5).
6. Pull the grommet (6) out of the mounting plate and slide it up
the shaft of the transducer (7) until it is clear of the mounting
plate.
7. Using a wrench, loosen and remove the transducer (7) from
the filter housing (8). Carefully thread the transducer wire out
through the mounting plate.
8. Slide the grommet (6) off of the old transducer (7) and onto
the new transducer.
9. Thread the new transducer wire through the mounting plate
and back to the motor controller (5).
10. Thread the new transducer (7) into the filter housing (8)and
tighten securely with a wrench.
i
Make sure the o-ring on the transducer is in place
before threading the transducer into the filter
housing.
11. Push the grommet (6) into the mounting plate.
12. Connect the transducer wire to the motor controller (refer to
the Connection Diagram, section 11.7).
13. Place the motor cover (4) back over the motor controller (5).
Secure with the two motor cover screws (3).
14. Slide the motor shroud (2) over the motor assembly.
15. Secure the motor shroud (2) with the two motor shroud
screws (1).