6.7

Monitoring flushing process

The flushing canister is equipped with a sight glass allowing to user to monitor the flushing
progress and the status of the flushing agent (refrigerant).
This feature also gives to the user the possibility to visualize the nature of the contamination
transported by the refrigerant.
There are two possibilities to consider if the flushing process is completed:
To let the program run by itself, until the selected flushing cycle is fully completed.
(single pass or multiple pass modes)
To monitor the refrigerant passing through the sight glass and decide at which moment
the flushing phase can be considerate as completed. When the flushing agent becomes
clear, the operator could assume that oil, UV additive and loose particles have been
removed from the system. In this case the user can short the process by pressing the
Stop key.
Flushing canister equipped with sight glass
Flow
Sight
glass
showing
contaminated with durty oil or miscelleneous
particles
ACKF01_GB_00
the
flushing
agent
Sight
glass
showing
contaminated with UV additive
Sight glass showing the flushing agent cleared
from any contamination. The A/C system is
clean.