7.9
Messages
The following Messages appear in occurrence of alarm, anomaly or request of maintenance.
The appearance of one of these malfunction/error messages is accompanied by a
beeper.
W a r n i n g
I n t e r n a l
O v e r p r e s s u r e .
The message appears during the recycling phase in case of hot temperature or/and internal
vessel at the limit of pressure capacity. Wait 30 min. to cool down and, if the problem persists,
contact TEXA S.p.A. or an authorized dealer.
Press ENTER three seconds to exit.
W a r n i n g
I n t e r n a l
F i l l e d .
P l e a s e
The message appears during the recovery phase if tank is full. Decrease the refrigerant
quantity in the internal vessel.
Press ENTER three seconds to exit.
W a r n i n g
P r e s s u r e
A / C
s y s t e m .
R e c y c l i n g
The message appears at the beginning or during the vacuum phase if pressure is detected
inside the A/C system.
L e a k a g e
E n t e r
t o
The message appears during the leak test phase. Verify A/C system.
In addition, the display shows the vacuum value in mbar.
Press Enter to continue or Stop to exit.
ACKF01_GB_00
!
v e s s e l
!
v e s s e l .
w a i t .
!
i n s i d e
s t a r t
!
c o n t i n u e .
m B .
TEXA S.p.A.
t h e
x x x
116/122