Installation - Aprimatic G-MATIC AP350 Instrucciones Para La Instalacíon Mecánica, El Uso Y El Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6.2

INSTALLATION

and regulate the motor torque to a minimum.
2
Use 0,5mm
wires to make connections to the pushbuttons, photocells and 24V power supply. For connections to the
electric lock, flasher and motors it is necessary to use at least 1,5mm
connections to supply mains of 230V 50Hz.
M1 terminal board
START
Normally open pushbutton (opening / closing)
STOP
Normally closed pushbutton (stop)
ST.P
Normally open pushbutton (pedestrian opening)
PHOTO1
Normally closed input external photocell
PHOTO2
Normally closed input internal photocell
COM
Common for inputs and warning light
+24V
Positive supply accessories 24V cc
- 24V
Negative supply accessories 24V cc
W.LIGHT 2W 24V
Warning light 24V 2W max
LOCK
Electrical lock 12V AC
SAFETY
Normally closed safety contact
T.PH
Photocell test contact (*)
(*)= To use the photocell test connect TX photocell negative contact to M1 contact 14 T.PH.
M2 terminal board
PE
Input ground
L
Input 230V 50Hz Line
N
Input 230V 50Hz Neutral (Flash light common contact)
FLASH
Flash light 230V 50Hz 15W max
Motor1 COM
Common coils motor 1
Motor1 C
Closing windings motor 1
Motor1 O
Opening windings motor 1
Motor2 COM
Common windings motor 2
Motor2 C
Closing windings motor 2
Motor2 O
Opening windings motor 2
It is necessary to clamp the cables of the M1-signals terminal board to M2-power terminal separately.
Fit a jumper cable on the normally-closed contacts when they are not in use.
OTHER THAN THE THOSE FOR WHICH THEY WERE DESIGNED.
If one of the normally-open inputs (START ad STOP) is closed, or one of the normally-closed inputs is open, the TEST
LED flashes at high frequency.
In this case it is not possible to carry out the learning strokes procedure.
DS41035-001
Before making the electrical connections it is necessary to turn off the mains of 230V 50Hz
DO NOT CONNECT THE FLASHER OR OTHER FITTINGS TO ANY TERMINALS
2
wires. Use wires of at least 2,5mm
25
2
to make
LBT0197

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

41035/80041035/801

Tabla de contenido