Regulations; Acquisition Remote Controls; Start Function; Pedestrian Start Function - Aprimatic G-MATIC AP350 Instrucciones Para La Instalacíon Mecánica, El Uso Y El Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6.5

REGULATIONS

The TR1 DELAY trimmer regulates the timing of the pause (the time the gate remains still before being closed
automatically), which varies from 1 to 120 seconds
The TR2 TORQUE trimmer regulates the torque of the motors.
REMARK: For motors equipped with a clutch or for oil-pressure motors it is necessary to rotate the TR2 TORQUE
trimmer to the maximum extent possible (i.e., a complete clockwise rotation).
The TR3 SLACK regulates the speed at which the timing is slowed, which can be regulated within the safety parameters.
REMARK: By regulating the TR3 SLACK trimmer to the maximum extent possible (i.e., a complete clockwise rotation),
the slowing does not take place (see learning procedure without slowing).
TRIMMER
TR1
TR2
TR3
6.6

ACQUISITION REMOTE CONTROLS

The AP 350 equipment is equipped with a built-in decoder able to memorize up to 128 rolling-code remote controls in
addition to fixed-code remote controls.
6.6.1

START function

In closed-gate mode, press the PROG.B button and hold it down until the TEST LED starts to flash. Release the
PROG.B button.
Within 10 seconds, set the remote control button that you want to connect to the START command. The completion of
the process will be indicated by the simultaneous flash of the TEST LED, of the flasher and of the pilot lamp, followed by
the termination of the flashing of the TEST LED.
With rolling code remote controls, repeat the process for each remote control to be set. With fixed-code remote controls it
is sufficient to carry out the process for only one model.
6.6.2

PEDESTRIAN START function

In closed-gate mode, press the PROG.B button and hold it pressed until the TEST led starts to flash; don't release the
button and wait until the flashing speeds up. Release the PROG.B button.
Within 10 seconds set the button of the remote control to learn and to be connected with the PEDESTRIAN START
control. When the learning has been carried out it will be indicated by the simultaneous flash of the TEST led, flasher
and of the pilot lamp, followed by the termination of the flashing of the TEST led.
In case of rolling code-type remote controls repeat the operation for each remote control to learn. In case of fixed-type
remote controls it is sufficient to carry out the learning of one single model.
6.6.3

Complete cancellation of the acquired remote controls

In closed-gate mode, press the PROG.B button and hold it pressed till when the TEST led starts to flash; don't release
the button and wait until the flash gets quicker; don't release the button and wait until the flash gets very quick; don't
release the button. When the blanking /blackout of ALL the learned remote controls has been carried out it will be
indicated by the simultaneous flash of the TEST led, flasher and of the pilot lamp, followed by the termination of the
flashing of the TEST led.
6.7

MAINTENANCE

There are two 5x20-size fuses on the board that protect the 230V line and the secondary of the transformer.
The fuse have the following values
230V line
F1 =
5A
Secondary
F2 =
2A
power of these fuses must not be modified.
There is no other component on the board that can be repaired or replaced by the installation personnel.
For any other intervention it is necessary to contact technical support.
DS41035-001
Function
DELAY
Pause time
TORQUE
Motors torque
SLACK
Slowing speed
fast
fast
Before replacing the fuses it is necessary to turn off the 230V mains power supply. The
Range
1 to 120 sec
20 to 100%
0 to 100%
27
Special functions
-
100% = clutch
100% = no slowing
LBT0197

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

41035/80041035/801

Tabla de contenido