Horizontal levelling and vertical levelling
– Horizontal: Position the device on a level surface or on a tripod.
– Vertical: Set the unit on its side feet. The operator panel should be
at the top. With the optional wall bracket (product ref. 080.70),
the device can be mounted on a tripod for vertical usage.
– Press the „ON/OFF" switch
!
The rotary laser aligns itself automatically once it is turned on.
– The device levels itself automatically to within a range of ± 6°. During the set-up phase, the laser flas-
hes and the prism head remains stationary. When levelling is complete, the laser lights up continuously
and rotates at maximum speed. Refer also to the sections about „Sensor Automatic" and „ADS Tilt".
If the device has been placed on a surface with too much of a slope (more than 6°), the prism
!
head will remain stationary and the laser will flash and emit a warning sound. The device must
then be placed on a more even surface.
Positioning the vertical laser level
In vertical mode the laser level can be positioned exactly. „Sensor Automatic" remains active and levels
to the vertical laser level. Refer to the illustration below.
!
When the maximum slope range of 6° has been reached, the laser will stay fixed and blink and
emit a sound. In this case, reduce the slope angle.