The appliance has been tested before being put
into service. The information provided below
is intended to assist in the identifi cation and
correction of any anomalies and malfunctions
which might occur during use.
The user can solve some of these problems
himself, but for others specifi c technical knowl-
edge or skill is required, and so they must only
be carried out by qualifi ed staff with recognised
experience acquired in the specifi c sector of
operation.
Faults
Smell of gas
The fl ame is yellow
The control panel does not
come on
The information provided below is intended to
identify the alarm signals which appear on the
display (A).
GB
Alarm
E01
Failure probe in the cooking well
E02
Electronic circuit board diagnostics
E05
Electronic circuit board diagnostics
E06
3329640_ut_GB
FAULT
TROUBLESHOOTING
Occasional leak because fl ame
has gone out
Burner dirty, heat exchange
pipes clogged, condensation
Electronic circuit board not
receiving electrical power
TABLE OF ALARM INDICATIONS
Causes
Core probe failure
tripped.
tripped
Important
For all requirements contact the agents or
the headquarters of Angelo Po which can be
found in the contacts section of the website
http://www.angelopo.com.
Causes
drips
A
Replace the cooking well probe
Sostituire la sonda la cuore
The appliance's functions are disabled so no
cooking cycles can be carried out.
Contact the after-sales service.
The appliance's functions are disabled so
no cooking cycles can be carried out.
Contact the after-sales service.
- 18 -
Remedies
Turn off the gas supply tap and
ventilate the room
Contact the after-sales service.
Check or swap the phase wire
connections
Remedies
ENGLISH