2.2.10
RIOJA AND COLISEO MODELS
PLACING / REPLACING THE STANDARD FRAME
The Rioja and Coliseo models incorporate a standard three-sided frame. Optionally you can purchase the lower profile of the frame to convert
it into 4 sides. Its installation is quite simple (see drawing D36):
1.
In order to place the lower profile, it is not necessary to remove the standard frame.
2.
On each side of the insert, you will find 2 holes.
3.
You must place the lower profile on the holes and screw the supplied screws.
4.
The profile must be perfectly adjusted either frontally or laterally to the standard frame.
2.2.11
PANAMÁ SERIES
Auxiliary ventilation
The models Panamá-E and Panamá-F have a tangential turbine
of 680 m3/h. However, the Panamá-D incorporates two turbines
of 450 m3/h. You can disable the operation of the turbine from the
control unit of the equipment, leaving it with natural convection.
However, if the insert reaches a temperature above TSI (by default
100°C), the turbine/turbines will work in automatic mode for cooling.
The turbine serves to propel the air, never to suck the hot air. The
position of the probe is shown in drawingsD37 (Panamá-F and E)
D38 (Panamá-D)
It is possible to direct one or more hot air exits to a different room
and not to the one where the insert is installed.
In that case, it is necessary to compensate this exit with a return canalization in order to prevent the room is in depression, with the risks that
this would entail.
The models Panamá-E and Panamá-F have a ventilation unit (turbine) of 680 m3/h incorporated in the bottom.
The ventilation unit takes air through the two side entrances (Ø150mm) of the fan which must be necessarily connected to a duct that takes
air cold enough in order to avoid the overheating of the equipment. This duct must be connected to the outside of the house or at least
outside the masonry built around the insert, aspirating the air of the room where it is installed. Otherwise, the combustion of the equipment
may not be appropriate because the turbine will take the O2 of the air intakes 1 and 2, diminishing the correct combustion of the equipment.
Do not forget the electrical connection of 220V and the grounding of the equipment. ATTENTION! This factor is crucial for the proper
operation. The turbines of the Panamá-D model lack this connection Ø 150 of the turbine.
Replacement of electrical components
In order to access to repair/replace the turbine, in case of failure, it is essential to provide a register during the installation in the lower-middle
part of the coating or masonry. This register can be a grate of minimum measures 400x250 mm (width x height).
In this way, it is possible to unscrew the box that contains the turbine and proceed to change it.
Electrical connection
First, disconnect the electrical power before any manipulation.
Second, connect the temperature probe supplied with the unit according to the attached plan so that it detects the temperature of your
equipment (drawing D37 and D38).
External air intake
The models Panamá-E and Panamá-F have the possibility of choosing that the primary, secondary or tertiary air intake comes from an
adjacent room (or even from outside the house) or from the same room where the insert is installed.
The air intakes of this model are located in the bottom, so in case that the insert is not channeled to the outside, we recommend unscrewing
the 6 screws of the connection cover and remove it so that the air flows through their respective intakes (see drawing D39). However, in the
Panamá-D model it is compulsory to connect the primary, secondary and tertiary air intake to an adjacent environment or outside the house.
In the case of deciding bring air from the outside or from an adjacent room, simply connect this intake through a pipe of diameter 120mm.
Note that a connection too long or with too many deviations (elbows), far from benefiting the contribution of air intake, causes a high load loss
and, therefore, may cause combustion problems.
Do not forget that this air intake is separate and distinct from the one necessary of the ventilation unit (turbine of 680 m3/h) of its turbine/
turbines with an ambient cold enough (outside the house or outside the masonry built around the insert).
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
35
D37
D36
D38
INSERTS