Placement of doors in Panama-D
The Panama-D model has two doors. If you need to remove these doors to facilitate the
installation process of the insert, remember to place the doors later in the correct position,
to ensure the correct operation of the equipment. These doors are not interchangeable.
It should be noted that the door that is placed on the side with the air regulations as well
as the ash drawer has a ceramic cord in the bottom to generate the sealing with the ash
drawer (see drawing D40).
D41
3.
INSTALLATION AND SAFETY INSTRUCTIONS
The way of installing the insert will affect the safety and the proper operation. For this reason, it is recommendable that the installation is
carried out by people who are qualified and informed about the compliance with the installation and safety norms. If an insert is not properly
installed it may cause serious damage.
Before the installation, follow the next verifications:
•
Make sure that the floor can sustain the weight of the equipment and make a proper isolation in the case that it is made of flammable
material (wood) or a material that can be affected by a thermal shock (plaster cast, for example). If the equipment is installed on a
floor which is not completely refractory or inflammable such as parquet, carpet, etc, it is necessary to replace this part or introduce a
fire-resistant base so that it protrudes out the fireplace 30 cm. Example of materials include steel flooring, glass base or any other type
of fire-resistant material.
•
Make sure that there is proper ventilation in the place where it is installed (air intake) (see section 5 of the manual).
•
Avoid the installation in places where there are collective ventilation pipes, hoods with or without extractor, B type gas equipments,
heat pumps or equipments that can cause that the draw of the chimney is not good if they are used at the same time.
•
Make sure that the smoke duct and the pipes used for the chimney are suitable for the operation of the insert.
•
We recommend that you call your fitter in order to check both the chimney as well as the air flow for the combustion.
•
This product can be installed near the walls as long as the they comply with the following requirements:
•
The fitter must assure that the wall is completely made of brick masonry, thermo-clay block, concrete, bricks, etc, and that it is coated
by materials that can support high temperature.
•
Therefore, for any other type of material (drywall, wood, non-ceramic glass, etc), the fitter must provide sufficient insulation or keep a
minimum safety distance to the wall of 80-100 cm.
•
Keep any flammable or heat sensitive materials (furniture, curtains, and clothing) at a minimum distance of about 100cm, including the
area in front of the loading door. Measurements below the minimum distances should not be used.
3.1.
SAFETY MEASURES
During the installation of the equipment, there are risks to be taken into account, so you should follow the next safety measures:
a.
Do not place flammable objects above.
b.
Do not place the insert near combustible walls.
c.
The insert should only be used when the ash pan is inserted.
d.
It is recommended to install carbon monoxide detector (CO) in the room where the equipment is installed.
e.
Use the glove included for opening and closing the door as well as manipulating the controls as these can be very hot.
f.
Solid combustion residues (ashes) should be collected in an airtight container and resistant to fire.
g.
The appliance should never be turned on in the presence of emission of gases or vapours (e.g., linoleum glue, gasoline, etc).
h.
Do not place nearby flammable materials.
WARNING!!
It is noted that both the insert and the glass get very hot and should not be touched.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
The door on the other side of the insert only has a ceramic cord to ensure the sealing of
the combustion chamber (see drawing D41).
36
D40
D39
INSERTS