Functional Description; On-Site Window Contact Switch - GUTMANN CARTA Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 98
EN
(for exhaust air operation) :
Contact closed !
Fume extractor operation only with
opened window or
supply air duct possible
Please note that your gas boiler or open fireplace will produce exhaust gases through
convection of the heated exhaust air from your living spaces to the outside.
Your exhaust fume extraction works by forced convection and therefore causes a
negative pressure in the living space, which sucks in the exhaust gases and/or the
exhaust gases of their house co-inhabitants from the chimney brings back.

Functional description:

The control of your GUTMANN cooker hood is equipped with a window contact cir-
cuit.If the contact loop of the controller is interrupted, the power supply to the fan mo-
tor is interrupted. The GUTMANN cooker hood lighting continues to function.
Only window contact switches approved by DIBt (Deutsches Institut für Bau-
technik) may be connected potential-free to the contact loop.
The contact must be closed when the window is open!
( pressure switch not actuated = shot ) ( reed switch open in magnetic field )
For detailed wiring options, please refer to the window contact brochure request.
48
Contact open !
Operation with closed window
deactivated if suction from
exhaust emission possible
( e.g. by gas heating or open fire )

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

75007510

Tabla de contenido