Descargar Imprimir esta página

How To Use The Control Panel - Rothenberger ROKLIMA PLUS 4F Instrucciones De Uso

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 30
INSTRUCTIONS FOR USE AND MAINTENANCE
Pressure gauges
The ROKLIMA PLUS 4F unit is equipped with 3xØ80mm
pressure gauges (depending on the model) with different
scales of coolant, dry regulated, with "Pulse Free"
braking movement that keeps the reading index free of
vibrations.
Flexible tubes
The ROKLIMA PLUS 4F unit is equipped with 3x2500 mm
flexible tubes (depending on the model) with intermediate
valve.
Their flexibility assures maximum ease of connection in
any situation; their role is to support the working pressures
from the A/C installation and maintain the flow section
intact even when working at low pressure.
Scales
The ROKLIMA PLUS 4F unit is equipped with an electronic
scale reading up to 100 Kg.
Programming system
The ROKLIMA PLUS 4F unit is equipped with a state of
the art programming system that carries out all operations
automatically It has 4 buttons and 2 LED lights.
It is also equipped with an acoustic indicator and an
interactive menu system in different languages.
Coolant bottle holder
The ROKLIMA PLUS 4F unit is equipped with 3 supports
(depending on the model) for 1 Litre and 2.5 Litre
bottles:
- Adapted for bottles R410A, R407C y R22
The user must use the appropriate support, depending on
the coolant that is to be used
Other components
Each unit includes the following components:
- two reducers 1/4" SAE female x 5/16" SAE male
- a mineral oil container for the vacuum pump
15
4. How to use the ROKLIMA PLUS 4F unit
4.1 Preparing the ROKLIMA PLUS 4F unit
4.1.1 Placement of the oil into the vacuum pump:
- Loosen filler cap no. 6 located on the upper part of
the pump.
- Fill with oil until the indicated level is reached at the
halfway mark on the visor of the
pump.
- Tighten the filling cap again.
4.1.2 Connection of the ROKLIMA PLUS 4F unit to the
A/C system
- Place the scales horizontally, after completely unwinding
the power cable.
- Place the bottle in the centre of the scales plate and
connect the capillary tube No. 10 to the bottle's liquid
intake, using the appropriate included reducer.
- Select the pressure gauge with the scale for the desired
coolant and connect it to coupling no. 9
- Select the flexible tube with the appropriate connections
for the system on which we are working and connect it
to connection no. 1
- Connect the flexible tube to the A/C system

4.2. How to use the Control panel

Thanks to the microprocessor and the electronic scale,
the ROKLIMA PLUS 4F unit is fully managed through a
computerised system, and can be controlled through the
buttons in the front panel. The ROKLIMA PLUS 4F unit
has a good-sized control panel for easy reading, even in
the poorest lighting conditions, thanks to its back light
system; the control panel enables the reading of the
parameters linked to the selected function and, if an
error should occur, it marks the appropriate error code.

Publicidad

loading

Este manual también es adecuado para:

1000000138