R70/1AC
POWER SUPPLY
NUMBER OF ACTIVATED MOTORS
MAXIMUM MOTOR POWER
MAXIMUM POWER FOR FLASHING LIGHT
MAXIMUM POWER FOR COURTESY LIGHT
MAXIMUM POWER FOR OPEN GATE INDICATOR LIGHT
MAXIMUM POWER FOR ACCESSORIES OUTPUT
WORKING TEMPERATURE
TORQUE ADJUSTMENT
OPERATING TIME
PAUSE TIME
ENCODER SETTINGS
PEDESTRIAN GATE OPENING TIME
4
230 Vac +/- 10% 50 Hz
1 asynchronous single-phase
400 W 230 Vac
40 W 230 Vac
100 W 230 Vac
2 W 24 Vac
300 mA 24 Vac
-10°C +55°C
with autotransformer on 4 positions
adjustable from 2 to 60 seconds, extendable up to 120
adjustable from 0 to 90 seconds
with encoder control
adjustable from 2 to 60 seconds, extendable up to 120
R70/1AC
CONNECTIONS TO THE TERMINAL BLOCK
1-2-3 F-N-Terra Board power supply INPUT 230 Vac 50 Hz.
6-5 LAM-CLU Courtesy light OUTPUT (230 Vac 100Wmax). Fixed voltage 230 Vac for motor operating time.
4-5 COR-CLU Flashing light OUTPUT (230 Vac 40Wmax). Fixed voltage 230 Vac for motor operating time (possibility to
increase of 60 sec - DIP SWITCHES 4).
7-8 SC-COM Open gate indicator light OUTPUT (24Vac 2Wmax). Always ON during the opening, pause and closing cycle;OFF
when gate in closed.
9-8 24Vac-COM Accessories power supply OUTPUT (24 Vac 300mAmax).
10-8 TST-COM OUTPUT (24 Vac 300mAmax). Use this to power the photocells when the TEST function is enabled.
12-11 COS-COM Safety edge INPUT (NC). During opening it generates a closing movement for approx. 3 sec. followed by
a stop. During closing it generates an opening movement for approx. 3 sec followed by a stop.
13-11 Foto-COM INPUT (NC) Photocell (FOTO). Ignored during the opening, inverts during the closing.
14-15 ST-COM Stop INPUT (NC). Generates the immediate stopping of movement in any position.
16-20 PED-COM Pedestrian opening INPUT (NO). The time of operation for opening is set by the trimmer A PED.
17-20 PP-COM Step-by-step INPUT (NO). Operating sequence: open-stop-close-stop...after the control unit is switched on,
the first command is Open.
18-20 CH-COM Close Input (NO).
19-20 AP-COM Open Input(NO).
21-22 2° CH Radio board 2
channel OUTPUT.
nd
23-24 CALZA-CENT. Antenna INPUT for radio board.
27-26 FCC-COM Motor limit switch for CLOSE position INPUT (NC).
28-26 FCA-COM Motor limit switch for OPEN position INPUT (NC).
0B-24B/0A-12A 0-24/0-12 Voltages from transformer INPUT.
TR-TN-TF Autotransformer power supply OUTPUT.
AP-CM-CH Motor OUTPUT (single-phase asynchronous 230Vac 400Wmax).
ADJUSTMENTS
TRIMMER T. LAV. To set the operating time from a minimum of 2 seconds to a maximum of 60 seconds; it is possible to
double the operating time (dip N° 6 a ON).
TRIMMER T.PAUSA To set the pause time from a minimum of 0 seconds up to a maximum of 90 seconds and only active if
automatic reclosing is set (dip N° 1 a ON).
TRIMMER A.PED To set the pedestrian gate opening time motor, from a minimum of 2 seconds up to a maximum of 60
seconds.
TRIMMER ENC: To set the anti-crushing sensitivity.
ADJUSTMENT OF THE TORQUE
Adjustment of the torque through selectable four-setting autotransformer (1 minimum 4 maximum)
DIP-SWITCHES SELECTIONS
DIP SWITCH N° 1: ON Enables automatic closing. After a complete opening cycle, when the PAUSE TIME set by the trimmer
has elapsed, the gate closes automatically.
DIP SWITCH N° 2: ON Closure after a blackout. After a blackout, the control unit automatically carries out the closing cycle.
DIP SWITCH N° 3: ON Enables pre-flashing. The flashing light is activated 4 sec. before to the start of movement.
DIP SWITCH N° 4: ON Enables a longer courtesy light. The courtesy light output remains active for another 60 sec. after the
end of movement.
DIP SWITCH N° 5: ON Enables the release thrust. When the gate is fully closed, an open or step-by-step command
generates an initial closing movement of the gates before opening starts. This helps release the electric lock.
DIP SWITCH N° 6: ON Enables doubling of the operating time. It sets the maximum OPERATING TIME at 120 sec.
DIP SWITCH N° 7: ON The step-by-step command becomes shared. The step-by-step command usually only generates
opening; when it is completely opened, it generates a closing.
DIP SWITCH N° 8: ON O Enables DEADMAN operation. The OPEN or the CLOSED key must be pressed continuously to
carry out the movement.
DIP SWITCH N° 9: ON When the gate is open, it closes again after 6 sec. Passing in front of FOTO. Passing in front of
FOTO1 generates reclosing of the gate after 6 sec. with or without automatic closing enabled.
DIP SWITCH N° 10: ON When the gate is closed, this allows opening even with the photocell darkened.
DIP SWITCH N° 11: ON Change of operation of FOTO. Interruption of the beam during OPENING is ignored.
Interruption of the beam during CLOSING generates a temporary stop until the beam is restored, at which point the door or
gate reopens.
DIP SWITCH N° 12: ON Activation of the BRAKE function. When the limit switch for the open or close position is reached,
the motor is braked for a moment.
OPERATION SELECTOR TST: TEST FOTO ENABLED
The FOTO test checks that the photocell is working properly before every opening cycle. The photocells must be connected to
terminal No. 18 TST.